:::ÇöÀçÀ§Ä¡ HOME ¢º Áß°íÁ¦Ç° ¢º Àü¿ø±â±â(AC/DC ÆÄ¿ö¼­ÇöóÀÌ/³»Àü¾Ð½ÃÇè±â/ÁÖÆļöº¯È¯±â/¼Ò½º¸ÞŸ) AC Voltage/Current Standa/½½¶óÀÌ´Ú½º ¢º DC Power Supply(ÆÄ¿ö¼­ÇöóÀÌ) ¢º ps20-54 DC Power Supply
    
 
 
ps20-54 DC Power Supply
ºê·£µå : 02
 
 
 
¢Â Á¦Ç°¼³¸í

* ¼ÒÇü °æ·®ÀÇ °í¼º´É : Å©°í ¹«°Å¿î ÀϹÝÀûÀÎ Àü¿ø °ø±Þ±âÀÇ Àý¹ÝÁ¤µµÀÇ Å©±â·Î °¡º­¿ì¸ç °í¼º´ÉÀ» ¹ßÈÖ

* Àü¾Ð,Àü·ù µðÁöÅРǥ½Ã : Àü¾Ð°ú Àü·ù Ãâ·Â ·¹º§À» 7 ¼¼Å©¸ÕÆ® LED·Î µ¿½Ã¿¡Ç¥½Ã

* GP-IB ½Ã½ºÅÛ °â¿ë¼º : Ãâ·Â Àü¾Ð°ú Àü·ù, ´Ù¾çÇÑ ½ÅÈ£ Ãâ·Â,Ãâ·Â°ú Àü¿ø On/Off ½ºÀ§Ä¡¿Í ¿ø°Ý/·ÎÄà ºÐ¸®±â¸¦ Á¶ÀýÇÒ ¼ö ÀÖ´Â Á¦¾î±â¸¦ °®Ãß°í ÀÖÀ¸¸ç GP-IB Á¦¾î ½Ã½ºÅÛÀ¸·Îµµ Á¶Á¤°¡´É(¼±Åûç¾ç GP-600)

* Æø ³ÐÀº ÀÀ¿ë : Ãâ·Â Àü¾Ð°ú Àü·ù´Â ¿ÜºÎ Àü¾Ð Á¦¾î¿Í ¿ÜºÎ ÀúÇ× Á¦¾î¸¦ Æ÷ÇÔÇÏ¿© ´Ù¾çÇÑ ¹æ¹ýÀ¸·Î Á¶Á¤ °¡´É

* ³·Àº ³ëÀÌÁî : ³Ã°¢ÆÒÀÇ ¸ðÅÍ´Â ¿Âµµ ¼¾¼­¿¡ ¿¬°áµÇ¾î ÀÖ¾î ºÎÇÏ ¶Ç´Â ¿Âµµ°¡ ³·À»¶§ ÀÚµ¿À¸·Î ÆÒ ¼Óµµ¸¦ ³·Ãß¾î °úµµ ³ëÀÌÁ ¹æÁöÇϴµ¥ µµ¿òÀÌ µÊ

* Àü¸é °ø±â ÈíÀÔ±¸ : °í¹Ðµµ ·¢¿¡ Àß ÀåÂøµÉ ¼ö ÀÖµµ·Ï Á¦À۵ǾúÀ¸¸ç, Àü¸é Ædz¾ÀÇ ±×¸±À» ÅëÇØ °ø±â°¡ ÈíÀÔÇÏ´Â ¹æ½ÄÀ» »ç¿ëÇÏ¿© °­·ÂÇÏ°Ô ³Ã°¢ ÇÒ ¼ö ÀÖÀ½.
Àü¸é ±×¸±¿¡´Â Á¦Ç° ³»ºÎ·Î µé¾î¿À´Â ¸ÕÁö¸¦ ¸·±â À§ÇÑ °ø±â ÇÊ´õ°¡ ³»Àå

* µðÁöÅÐ µð½ºÇ÷¹ÀÌ : Àб⠽¬¿î 7 »¡°£ ¼¼Å©¸ÕÆ® Ç¥½Ã±â´Â Àü¾Ð°ú Àü·ù ·¹º§À» µ¿½Ã¿¡ Ç¥½ÃµÇ¸ç Àü¾Ð°ú Àü·ùÀÇ 3-1/2 ÀÚµ¿ ¹üÀ§ Ư¡Àº °¢°¢ ÃÖ´ë 10mV¿Í 10mAÀÇ ºÐÇØ´ÉÀ¸·Î Ç¥½ÃµÊ
  Á¦Ç°»ç¾ç
Model Output CV (constant-voltage) characteristic CC (constant-current) characteristic Others
CV CC Ripple* Line regulation Load regulation Transient response** Rise time/ Fall time Ripple*** Line regulation Load regulation Input Current Case dimensions Weight
V A mV rms 0.05% mV 0.1% mV m sec m sec (Full loaded) mA rms 0.2% mA 0.2% mA AC (100/200V)A Type kg (approx.)
PS6-60  0 to 6 0 to 60 10 5 5 1 80/150 120 5 5 8/5 I 3.0
PS6-120 0 to 120 2 260 10 10 16/10 II 5.5
PS10-35 0 to 10 0 to 35 10 5 5 1 80/150 70 5 5 8/5 I 3.0
PS10-70 0 to 70 2 160 10 10 15/9 II 5.5
PS20-18 0 to 20 0 to 18 10 5 5 1 80/150 40 5 5 8/5 I 3.0
PS20-36 0 to 36 2 92 10 10  15/9 II  5.5
PS20-54 0 to 54 15 120 15 15 22/13 III  7.0
PS36-10 0 to 36 0 to 10 10 5 5 1 80/150 20 5 5 8/5 I 3.0
PS36-20 0 to 20 60  10  10  15/9 II 5.5
PS36-30 0 to 30 15 80  15  15  22/13 III  7.0
PS60-6 0 to 60 0 to 6 10 5 5 80/150 12 8/5 3.0
PS60-12 0 to 12 15 44 10  10  15/9 II  5.5
PS60-18 0 to 18 20  55  15  15  22/13 III  7.0
*1: Between 20 Hz and 1 MHz.
*2: The time taken by the output voltage to return to within 0.1% 10 mV of the set value when the output current is varied from 20% to 100% at 50% to 100% of the rated output voltage.
*3: Measured when the output voltage is between 1% and 100% of the rated voltage.
Common Specifications
Power source 85 to 132V /170 to 250V
AC 50 to 60Hz
Display instruments
Voltmeter Display 3-1/2 digits red LED
Accuracy 0.1%rdg¡¾2digits (23¡¾5¡ÆC)
Temperature coefficient ¡¾100ppm/¡ÆC (0 to 50¡ÆC)
Ammeter Display 3-1/2 digits red LED
Accuracy  0.5%rdg¡¾3digits (23¡¾5¡ÆC)
Temperature coefficient ¡¾200ppm/¡ÆC (0 to 50¡ÆC)
Protection
Overvoltage protection The power relay is tripped when the output voltage is exceeded by approx. 110%. of the rated voltage.
Overcurrent protection The power relay is tripped when the output current is approx. 110% to 130% of the rated current.
Overheating Protection The power relay is tripped when the temperature of the heat sink is approx. 100¡¾5¢®ëC or more.
Thermal fuse Built-in thermal fuse
Input fuse Cut off the power relay
Environmental condition
Temperature/humidity for operation 0 to 50¡ÆC/30 to 80%RH
Temperature/humidity for storage -20 to 70¡ÆC/20 to 80%RH
Cooling system Forced air (fan), front air intake type.
Functions  Automatic output switch resetting, voltage/current limit switch, preset OVP
Case dimensions
Type I  70 (W) ¡¿ 124 (H) ¡¿ 350
.5 (D) mm
Type II  140 (W) ¡¿ 124 (H) ¡¿ 350.5 (D) mm
Type III 210 (W) ¡¿ 124 (H) ¡¿ 350.5 (D) mm
Accessories 2.5m AC cable ¡¿ 1




 
 
»ç¾÷ÀÚµî·Ï¹øÈ£ 113-01-57596| ¼­¿ï½Ã ±¸·Î±¸ ±¸·Îº»µ¿1258 Áß¾ÓÀ¯Åë´ÜÁö °¡µ¿ 2413È£ Åë½ÅÆǸŠÁ¦ 1918È£ | ´ëÇ¥ÀÚ¸í ±èâ¼ö