:::ÇöÀçÀ§Ä¡ HOME ¢º ½ÅÁ¦Ç° ¢º ¿À½Ç·Î½ºÄÚÇÁ/ µðÁöÅпÀ½Ç·Î½ºÄÚÇÁ ¢º [HANTEK DSO-2150] PC BASED DIGITAL STORAGE 60MHz OSILLOSCOPE/USB ÈÞ´ë¿ë½ºÄÚÇÁ
    
 
 
[HANTEK DSO-2150] PC BASED DIGITAL STORAGE 60MHz OSILLOSCOPE/USB ÈÞ´ë¿ë½ºÄÚÇÁ
  ¢¹ °£´ÜÇÑ ¼³¸í
  Á¦Ç°ÄÚµå : DSO-2150
¿ø»êÁö : Áß±¹
Á¦Á¶»ç : HANTEK
 
 
 
DSO-2150 USB
SC 150MS/s, 60MHz bandwidth
Full
 1.Download:
¡¼32Driver¡½ ¡¼64Driver¡½ ¡¼Software¡½ ¡¼Manual¡½ ¡¼SDK¡½
 2.Acessories:

 

 

Product

Oscilloscope

 

                    Probe

 

                 USB cord

S/W CD

 

manual

 

  3. Other Pictures:   

 

 

4. Characteristic

  • USB2.0 interface, no external power source required, easy to use.
  • be suitable for notebook computer£¬product line maintenance£¬be used easily on business.
  • Dimensions (mm):190(L) x100(W) x35(H), be carried easily.
  • High performance, 150MS/s real-time sampling, 60MHz Bandwidth.
  • Operating System: Windows7,Windows Me, Windows NT, Windows 2000, Windows XP ,VISTA
  • 23 measurement functions, PASS/FAIL Check, be suitable for technical application.
  • Waveform average, persistence, intensity, invert, addition, subtraction, multiplication, division, X-Y plot.
  • Save waveform in the following: text file, jpg/bmp graphic file, MS excel/word file.
  • FFT
  • One computer can connect many DSO, extend channel easily.
  • LabviewVBVCDelphiC++Builder Second Design instance.

5. Hardware Specification

Channel

2 Channels

Bandwidth

60MHz

Max. Sample rate

150MS/s

Impedance

1M¥Ø 25pF

Coupling

AC/DC/GND

Vertical resolution

8Bit

Gain range

10mV-5V, 9Steps

DC accuracy

¡¾3%

Timebase range

4ns-1h, 38 Steps

Vertical adjustable

Yes

Input protection

Diode clamping

X-Y

Yes

Autoset

Yes (30Hz to 60MHz)

EXT. input

Yes

Trigger Mode

Auto, Normal and Single

Trigger Slope

+/-

Trigger level adjustable

Yes

Trigger Type

Rising edge, falling edge

Trigger Source

CH1, CH2, EXT

Pre/Post trigger

0-100%

Buffer size

10K-32KB/Channel

Shot bandwidth

DC to 60MHz

Sampling selection

Yes

Waveform Display

port/line, waveform average, persistence, intensity

Network

Open/Close

Vertical mode

CH1, CH2, Dual, ADD

Cursor measurement

Yes

Math

FFT, addition, subtraction, multiplication, division.

Cursor

Frequency, Voltage

Data Samples

10K-32K/Channel

Accessories

S/W CD, probes, manual, USB cord

 

6£®Software£º

Operating system:Windows 7, Windows Me, Windows NT, Windows 2000, Windows XP, VISTA.

 

7£®SecondDesign£º

    Supply DEMO code (VC¡¢CVI¡¢VB¡¢LABVIEW) and technical support.


 
 