½ÅÁ¦Ç°
Áß°íÁ¦Ç°
Àü±â¾ÈÀüÀåºñ
ESCOµî·ÏÀåºñ, ¿¡³ÊÁöÁø´ÜÀåºñ
½ÅÀç»ý¿¡³ÊÁö°ü·ÃÀåºñ
Á÷Á¢»ý»ê °Ë»ç¼³ºñ(¹ýÁ¤¼³ºñ)
write_poem
°øÁö»çÇ×
°í°´ °Ô½ÃÆÇ
Á÷°Å·¡ ÀåÅÍ
°í°´ ÀÚ·á½Ç
±¸¸Å|¸Å°¢ A/SÀÇ·Ú
 

  ¢Ï  °í°´¼¾ÅÍ

 TEL: 02-2616-4851

 FAX: 02-2616-4852

 H.P:010-3778-0143

 mail:kcs465@naver.com   

 
 
:::ÇöÀçÀ§Ä¡ HOME ¢º Áß°íÁ¦Ç° ¢º º¤ÅͽºÄÚÇÁ/¿þÀ̺êÆû¸ð´ÏÅÍ/Ä®¶óÆÐÅÏ/¿Àµð¿À¾Æ³¯¶óÀÌÀú/Ä®·Î¾Æ³¯¶óÀÌÀú/ ÈÖµµ°è ¢º ÈÖµµ°è ¢º CS-100A /ÈÖµµ°è
    
 
 
CS-100A /ÈÖµµ°è
 
 

»óÇ°»ó¼¼Á¤º¸

 
CS-100A
±¤¿øÀÇ ÈÖµµ, »öµµ ¹× ¹Ý»ç¹°Ã¼»ö ÃøÁ¤ÀÌ °¡´ÉÇÑ 1µµ ÃøÁ¤°¢ÀÇ °íÁ¤µµ ºñÁ¢ÃË½Ä ÈÖµµ°è ¹èÅ͸®·Î ±¸µ¿ÀÌ °¡´ÉÇÏ°í CompactÇÑ µðÀÚÀÎÀ¸·Î È޴뼺ÀÌ ¸Å¿ì ¿ì¼öÇϸç, °æ·®ÀÇ Body´Â °£´ÜÇÑ ½Ã½ºÅÛÀ» ²Ù¹Ì±â¿¡µµ Àû´çÇÔ

°¡º±°í CompactÇÑ µðÀÚÀÎ

ºñÁ¢ÃË ¹æ½ÄÀÇ ÃøÁ¤

1µµ ÃøÁ¤°¢ Àû¿ëÀ¸·Î Á÷°æ 14.4mm(ÃøÁ¤ °Å¸® 1014mm)±îÁö ÃøÁ¤ÀÌ °¡´ÉÇϸç, Close-up lens Àû¿ë½Ã¿¡´Â Á÷°æ 1.3mm±îÁöµµ ÃøÁ¤ °¡´É

»öÂ÷ ÃøÁ¤ °¡´É

User calibration °¡´É

cd/m2 ¹× fLÀÇ Luminance Unit ¼±Åà °¡´É


* Àû¿ë ºÐ¾ß

µð½ºÇ÷¹ÀÌ ÀåÄ¡ÀÇ ÈÖµµ¿Í »öµµ ÃøÁ¤

°¢Á¾ ±¤¿ø ¹× Á¶¸í ÀåÄ¡ÀÇ ÈÖµµ¿Í »öµµ ÃøÁ¤

Model

Chroma Meter CS-100A

Type

SLR spot colorimeter for measuring light-source and surface luminance and chromaticity

Measuring angle

1¢ª

Optical system

85mm f/2.8 lens; SLR viewing system; flare factor less than 1.5%

Angle of view

9¢ª with 1¢ª measurement area indication

Focusing distance

1014mm to infinity

Receptors

3 silicon photocells filtered to detect primary stimulus values for red, green and blue light

Spectral response

Closely matches CIE 1931 Standard Observer curves

Response time

FAST: Sampling time: 0.1s, Time to display: 0.8 to 1.0s; SLOW: Sampling time: 0.4s, Time to display: 1.4 to 1.6s

Luminance units

cd/mor fL

Measuring range

FAST 0.01 to 299,000cd/m2

SLOW 0.01 to 49,900cd/m2

Accuracy

Luminance(Y): ¡¾2% of reading ¡¾1digit

Chromaticity (x, y):

FAST Y 100cd/m2 or above: ¡¾0.001; 48.1 to 99cd/m2 : ¡¾0.002; below 48.1cd/m2: below measurement range

SLOW Y 25.0cd/m2 or above: ¡¾0.001; 12.0 to 24.9cd/m2 : ¡¾0.002; below 12.0cd/m2: below measurement range

(Measurement subject: Illuminant A)

Target value

1; set by measurement or numerical input

Measurement modes

Absolute color: Yxy; color difference: ¥Ä(Yxy)

Data communication

RS-232C

External control

Measurement can be started by external device connected to data output terminal

Power source

One 9V battery, Power can be supplied via data output terminal

Operating temperature/humidity range

0 to 40¡É, relative humidity 85% or less(at 35¡É) with no condensation

Storage temperature/humidity range

-20 to 55¡É, relative humidity 85% or less(at 35¡É) with no condensation

Size

79*208*154mm

Weight

890g

 
 
»ç¾÷ÀÚµî·Ï¹øÈ£ 113-01-57596| ¼­¿ï½Ã ±¸·Î±¸ ±¸·Îº»µ¿1258 Áß¾ÓÀ¯Åë´ÜÁö °¡µ¿ 2413È£ Åë½ÅÆǸŠÁ¦ 1918È£ | ´ëÇ¥ÀÚ¸í ±èâ¼ö
ÀÎâ°èÃø±â ÀüÈ­ 02-2616-4851 Æѽº 02-2616-4852
Copyright ÀÎâ°èÃø±â 2008 All rights reserved.