LS-100 / 110


»ç¿ëÇϱ⠽±°í CompactÇÑ µðÀÚÀΰú °¡º­¿î Áß·®À¸·Î ÈÞ´ëÇϱâ ÆíÇÏ¸ç ¿ø°Å¸® ÃøÁ¤µµ °¡´ÉÇÑ Àü¹® ÈÖµµ°è


SLR(Single Lens Reflex) optical system ä¿ëÀ¸·Î Flare Çö»óÀ» ¹æÁöÇÏ¿© Á¤È®ÇÑ ÃøÁ¤ °¡´É

LS-110ÀÇ °æ¿ì 1/3µµ Aperture¸¦ Àû¿ëÇÏ¿© ÀÛÀº ¿µ¿ªÀÇ ÃøÁ¤ °¡´É(Close-up Lens ÀåÂø½Ã Á÷°æ 0.4mm ¿µ¿ª±îÁö ÃøÁ¤ °¡´É)

RS-232 Åë½Å ¹æ½ÄÀÇ Remote Control

User Calibration Function

* Àû¿ë ºÐ¾ß 

µð½ºÇ÷¹ÀÌ ÀåÄ¡ÀÇ ÈÖµµ ÃøÁ¤

°¢Á¾ ±¤¿ø ¹× Á¶¸í ±â±¸ÀÇ ÈÖµµ ÃøÁ¤

±³Åë ½ÅÈ£µîÀÇ ÈÖµµ ÃøÁ¤


LS-100

LS-110

Type

SLR spot luminance meter for measuring light-source and surface brightness

Measuring angle

1¢ª

1/3¢ª

Optical system

85mm f/2.8 lens; SLR viewing system; flare factor less than 1.5%

Angle of view

9¢ª

Focusing distance

1014mm to infinity

Minimum measuring area

¥Õ14.4mm

¥Õ4.8mm

Receptor

Silicon photocell

Relative Spectral Response

Within 8%(f1') of the CIE spectral luminous efficiency V(¥ë)

Response time

Fast : Sampling time 0.1s, time to display 0.8 to 1.0s; Slow : Sampling time 0.4s, time to display 1.4 to 1.6s

Luminance units

cd/mor fL(switchable)

Measuring range

Fast : 0.001 to 299,900cd/m2

Slow : 0.001 to 49,990cd/m2

Fast : 0.01 to 999,900cd/m2

Slow : 0.01 to 499,990cd/m2

Accuracy

0.001 to 0.999cd/m2

:¡¾2%¡¾2digits of displayed value

1.000cd/m2

or greater:¡¾2%¡¾1digit of displayed value

0.01 to 9.99cd/m2

:¡¾2%¡¾2digits of displayed value

10.00cd/m2

or greater:¡¾2%¡¾1digit of displayed value

(Illuminant A measured at ambient temperature of 20 to 30¡É)

Repeatability

0.001 to 0.999cd/m2

:¡¾0.2%¡¾2digits of displayed value

1.000cd/m2

or greater:¡¾0.2%¡¾1digit of displayed value

0.01 to 9.99cd/m2

:¡¾0.2%¡¾2digits of displayed value

10.00cd/m2

or greater:¡¾0.2%¡¾1digit of displayed value

(Measurement subject : Illuminant A)

Temperature/humidity drift

Within ¡¾3%¡¾1digit(of value displayed at 20¡É) within operating temperature/humidity range

Calibration mode

Minolta standard/user-selected standard(switchable)

Color correction factor

Set by numerical input; range 0.001 to 9.999

Reference luminance

1; set by measurement or numerical input

Measurement mode

Luminance; luminance ratio; peak luminance or luminance ratio

Data communication

RS-232C

External control

Measurement process can be started by external device connected to data output terminal

Power source

One 9V battery, DP-10À» ÅëÇÑ power °ø±Þ

Operating temperature/humidity range

0 to 40¡É, relative humidity 85% or less(at 35¡É) with no condensation

Storage temperature/humidity range

-20 to 55¡É, relative humidity 85% or less(at 35¡É) with no condensation

Size

79*208*150mm

Weight

850g

 
 