Ư¡ (Features)
l DC3 ~ 60V ¿î¿ë Àü¾Ð
l 6mA ~ 60A ¿î¿µ Àü·ù
l 1 ~ 300W ¿î¿ë Àü·Â
l UP?DOWN ¹öÆ°À» ÀÌ¿ëÇÑ ½¬¿î Á¶ÀÛ
l °íºÐÇØ´É :20mV,0.2mA,0.33m¥Ø
l °úÀü¾Ð,°úÀü·ù,°úÀü·Â º¸È£
l 100°³ÀÇ ¼ÂÆà ¸Þ¸ð¸®
l ¿î¿ë ¸ðµå :Á¤Àü¾Ð ¸ðµå(CV),Á¤Àü·ù¸ðµå(CC) ,c Á¤ÀúÇ× ¸ðµå(CR)
l 1Hz ~1kHzÀÇ ¼ø°£ ¹ß»ý ÁÖÆļö ´ë¿ª
l 10% ~90% µà¾ó ¹üÀ§
»ó¼¼¼³¸í(Description)
PEL-300Àº ´ÜÀÏ Ãâ·ÂÀÇ 300W ±Þ ÀüÀÚ ·Îµå·Î »ç¿ëÀÌ ¸Å¿ì °£°áÇÏ°í ½¬¿î Á¦Ç°ÀÔ´Ï´Ù. ¶ÇÇÑ OVP.OCP.OPP ±â´ÉÀº ¿¹ÃøÇÏÁö ¸øÇÑ »óÈ¿¡¼ º»Ã¼¸¦ ¾ÈÀüÇÏ°Ô º¸È£Çϸç,ÁÖ¿ä ¾ÈÀü ±Ô°ÝÀÎ UL,CSA,IECµîÀ» ÁؼöÇÕ´Ï´Ù. 20mV,0.2mA,0.33m ÀÇ °íºÐÇØ´ÉÀº ¸Å¿ì Á¤È®ÇÑ ºÎÇÏ ½Ã¹°·¹À̼ÇÀ» °¡´ÉÇÏ°Ô Çϸç, ŸÀÌ¸Ó ¼ÂÆÃÀ» ºñ·ÔÇÑ ÀúÀå/Recall ¸¦ ÀÌ¿ëÇÏ¿© ½ÃÄý½º ÇÁ·Î±×·¡¹ÖÀ» ¸Å¿ì ´Ü¼øÈ ÇÏ¿© ÀÛ¾÷ÇÒ¼ö ÀÖ½À´Ï´Ù. PELdms ½ÇÇè½ÇÀ̳ª »ý»ê ¶óÀο¡¼ ¾ÈÀü¼º°ú ½Å·Ú¼ºÀÌ ¿ì¼±½Ã µÇ´Â °÷¿¡¼ ¸Å¿ì À¯¿ëÇÑ Á¦Ç°ÀÔ´Ï´Ù.
»ç¾ç (Specification)
RATING |
Operating Volatge |
DC 3 ~ 60V |
Operating Current |
6mA ~ 60A |
Operating Power |
1 ~ 300W |
MInimum Operation |
3V |
CV MODE |
Operating Range |
DC 3 ~ 60V |
Setting Accuracy |
¡¾(0.1% + 40mV) |
Setting Resolution |
20mV |
CC MODE |
Operating Range |
6mA ~ 60A |
Setting Accuracy |
¡¾(0.5% + 100mA) for 6.02A ~ 60A ¡¾(0.1% + 10mA) for 0.602A ~ 6A ¡¾(0.1% + 1mA) for 6mA ~ 0.6A |
Setting Resolution |
20mA for 6.02A ~ 60A 2mA for 0.602A ~ 6A 0.2mA for 6mA ~ 0.6A |
CR MODE |
Operating Range |
50m¥Ø ~ 1k¥Ø |
Setting Accuracy |
¡¾(5% + 1¥Ø) for 100.33¥Ø ~ 1k¥Ø ¡¾(5% + 100m¥Ø) for 10.033¥Ø ~ 100¥Ø ¡¾(5% + 10m¥Ø ) for 1.0033¥Ø ~ 10¥Ø ¡¾(5% + 1m¥Ø ) for 50m¥Ø ~ 1¥Ø |
Setting Resolution |
330m¥Ø for 100.33¥Ø ~ 1k¥Ø 33m¥Ø for 10.033¥Ø ~ 100¥Ø 3.3m¥Ø for 1.0033¥Ø ~ 10¥Ø 0.33m¥Ø for 50m¥Ø ~ 1¥Ø |
DYNAMIC OPERATION CC MODE ONLY |
Frequency Range |
1Hz ~1kHz |
Resolution |
5Hz for 100Hz ~1kHz 0.5Hz for 10Hz ~100Hz 0.05Hz for 1Hz ~10Hz |
Duty Range |
10% ~ 90% |
Resolution |
1% |
VOLTAGE READBACK |
Accuracy |
¡¾(0.1% + 60mV) |
Resolution |
20mV |
CURRENT READBACK |
Accuracy |
¡¾(0.5% + 100mA) for 6.02A ~ 60A ¡¾(0.1% + 10mA) for 0.602A ~ 6A ¡¾(0.1% + 1mA) for 6mA ~ 0.6A |
Resolution |
20mA for 6.02A ~ 60A 2mA for 0.602A ~ 6A 0.2mA for 6mA ~ 0.6A |
MEMORY |
|
100 sets |
TIMER |
Range |
1 second ~ 999 minutes 59 seconds |
Resolution |
1 second |
Function |
for load on |
POWER SOURCE |
|
|
AC100V/120V/220V/240V¡¾10%, 50/60Hz |
ACCESSORIES |
|
User manual x 1 Power cord x 1 |
DIMENSIONS & WEIGHT |
|
|
255(W) x 145(H) x 346(D)mm Approx. 9kg |
|
|