:::ÇöÀçÀ§Ä¡ HOME ¢º Áß°íÁ¦Ç° ¢º EMC EMI °ü·Ã±â±â(ÀÓÆÞ½º³ëÀÌÁî/½áÁöÁ¦³Ê·¹ÀÌÅÍ/Á¤Àü±â¹ß»ý±â) ¢º Surge Generat / Surge Comparison Tester (±Ç¼± Àý¿¬ ½ÃÇè±â) ¢º Keytek 587 pule Áß°í SURGE GENERATOR
    
Ãßõ»óÇ°
 
 
Keytek 587 pule Áß°í SURGE GENERATOR
ºê·£µå : 02
 
 
Surge Generator
Selectable surges for:
Keytek 587 Pule
Short branch circuits
- 1.2 x 50¥ìs impulse, to 6kV OCV*, 8 x 20¥ìs impulse to > 3kA SCI* (stored energy, 216 joules)
- .5¥ìs/100 kHz ring wave (damped cosine): to 6kV OCV*, 500A SCI* (stored energy, 7.2 joules)
Long branch circuits
- .5¥ìs/100kHz ring wave: to 6kV OCV*, 200A SCI* (stored energy, 7.2 joules)
Switch-selectable polarity
Meter to set peak output surge
Floating synch output just prior to surge
Full interlock system prevents surging unless all interlocks (including external) are closed.
Includes:

1. Model : Keytek 587 pule Surge Generator mainframe

2. Model P1 .5¥ìs/100 kHz ring wave plug-in Surge Network

6kV, 0.5¥ìs/100 kHz ring wave;
200A and 500A
Q ~ 3 and Q ~ 10
IEEE Std. 587-1980 (Cat. A plus first half of Cat. B); UL943, 217, 268
3. Model P3 1.2 x 50¥ìs impulse plug-in Surge Network

1.2 x 50¥ìs, 6kV
8 x 20¥ìs, ~ 3kA
IEEE Std. 587-1980 (second half of Cat. B); IEC 664
4. Model F31 Surge Coupler/Filter
Selectable surge coupling modes:

Normal mode: line 2 to line 1
All three common modes:
line 1 to ground
line 2 to ground
lines 1 and 2 to ground
Power line:
0-277 V, 50-60 Hz
0-120 V dc
To 10A continuous, 15A intermittent
* OCV = open circuit voltage
* SCI = short circuit current

Please contact us for more information on the Keytek 587pule



Surge Generator
Includes front-panel switching for surge polarity and test waveform, digital display of peak delivered open-circuit surge voltage and remote control feature. Also includes a line coupler-fitter for surging powered equipment, front-panel switching for normal mode/common mode selection and 4-wire output monitoring for oscilloscope display of delivered surge waves.

Includes PLUS plug-in, modular surge network construction to permit use of different surge networks. Allows surge testing not only to IEEE 587 and IEC 664 but also to CCITT and UL1449 surge specifications and to other standards as they are developed. The Model 587-Plus ¢ç offers the best of both worlds: economy, plus the broad versatility that results from modular design and construction.

Pictured with S1/S3 Surge Network:

Rotary switch selection of the Bi-Wave (the 1.2x50 6KV open-circuit, 8x20 3 KA short-circuit wave of ANSI C62 .41
category B) plus Rotary switch selection of the two CCITT waves (10x700, 100x700), plus an additional, 0.5x700 wave. Rotary switch selection of output damping resistor: 0, 2.5, 25 ohms.

 
 