:::ÇöÀçÀ§Ä¡ HOME ¢º Áß°íÁ¦Ç° ¢º EMC EMI °ü·Ã±â±â(ÀÓÆÞ½º³ëÀÌÁî/½áÁöÁ¦³Ê·¹ÀÌÅÍ/Á¤Àü±â¹ß»ý±â) ¢º Surge Generat / Surge Comparison Tester (±Ç¼± Àý¿¬ ½ÃÇè±â) ¢º ½áÁöÁ¦³Ê·¹ÀÌÅÍ(Key Tek ECAT)Rent Thermo Keytek ECAT w/ E510A Module, 10kv Surge
    
Ãßõ»óÇ°
 
 
½áÁöÁ¦³Ê·¹ÀÌÅÍ(Key Tek ECAT)Rent Thermo Keytek ECAT w/ E510A Module, 10kv Surge
  ¢¹ °£´ÜÇÑ ¼³¸í
  Rent Thermo Keytek ECAT w/ E510A Module, 10kv Surge Combination Wave for IEC/EN 61000-4-5  
 
 

SPECIFICATIONS

Standards MetANSI/IEEE C62.41 Cat. B and IEC 61000 4-5
Pulse voltage (open circuit)1.2/50µs, 0-10.1kV ¡¾10% in 1 volt steps
Combination wave pulse 1, 2/50 - 8/20 ¥ìs (Hybrid-Surge pulse)
Pulse conforms to IEC/EN 61000-4-5
ParameterValue
Pulse current (short circuit)8/20µs, 0-5.05kA with 2 ohm effective source impedance, ¡¾10%
Coupling1 PH / 15 (16) Amps
Repetition timeAdjustable from 300ms to 5s; 1ms resolution
Pulse repetition1 shot/18 seconds
Phase synchronization¡¾15¡Æ with optional coupler/decoupler
CouplingModel E4551 - Single Phase 16 Amps
Test duration¡¾20% Tolerance
Test duration1.0ms to 20ms; 1.0ms resolution or 1 to 200 pulses

TEST EQUIPMENT DESCRIPTION

ECAT E510A Module Description:

The Keytek ECAT Simulator System with E510A plug in is a 10 kV surge gernerator that is IEC 61000-4-5 compliant.

  • 1.2/50us - 8/20us; IEC coupling
  • Surge pulses up to 10kV/5kA 
  • Single phase or three-phase coupler up to 100A (external options, separate) 
  • Standard test routines

How to Order the ECAT System:

  • Click "Add to Cart" above
  • Shipping Section - Select "Use My Account" - we ship this system freight to keep it upright. Indicate in the Notes section if you'd like us to facilitate shipment or if your logistics team will do so.
  • Checkout Accordingly
  • An EMC Shop representative will contact you with shipping estimates or logistics details.

About the Keytek ECAT System:

The Thermo Fisher Keytek ECAT Simulator systems are a sesoned favorite being used for electromagnetic Surge and EFT testing for more than 2 decades. The controller has an easy-to-use Windows based application software for quick implementation of test routines and standards, with automoatic report generation. A multi-level system interlock architecture provides maximum safety to keep first time users safe.

This used ECAT system is suitable for users looking to evaluate DUT in a precompliance environment for passing Surge and Burst (Electrical Fast Transient) immunity test standards such as IEC 61000-4-4, IEC 61000-4-5 and ANSI C62.41. The single phase, 15 amp coupling network is suitable for most commercial electronics and lower powered electronics.

ECAT Surge Simulator Configuration:

  • E103 Controller (fiber-interface for remote control)
  • E411 EFT/Noise Burst Simulator to 4.4 kV (IEC 61000-4-4)
  • E510A Surge Simulator to 10 kV (IEC 61000-4-5, ANSI C62.41 Cat. B and UL 1449 at 5kA)
  • E4551A Single Phase Surge/EFT Coupler 250V rms (typ. 15 Amps)
  • Input voltage: 100V to 240VAC
  • Input Current: 3.5A at 100 V; 1.5A at 240 V
  • User Manual
  • NIST Calibration Certificate


KeyTek ECAT¢ç Model E510A 

Plug-in module to produce combination wave specified by ANSI/IEEE C62.41 Cat. B and IEC 61000 4-5 to 10kV and 5kA Electrical Open-Circuit Voltage 1.2/50µs, 0-10.1kV ¡¾10% in 1 volt steps Short-Circuit Current 8/20µs, 0-5.05kA with 2 ohm effective source impedance, ¡¾10% With the additional 10 ohm resistor, the peak short-circuit current = open-circuit voltage ¡À12, ¡¾10%. (The short-circuit current waveform is modified by the additional resistance.) Front Time Tolerance ¡¾30% for voltage ¡¾20% for current Duration Tolerance ¡¾20% voltage and current Surge Repetition Rate 1 shot/18 seconds Line Sync Accuracy +15¨¬ with optional coupler/decoupler Compatible Powerline E455x-kV, E4555, E4556 Coupler/Decouplers Minimum System Requirements E100 series control center Options E510A-VI - adds voltage and current monitoring


KeyTek ECAT¢ç Model E455x 

Single and three-phase AC line coupler/decouplers for EFT and Surge waves, as specified by IEC 61000-4-4 Edition 2 and IEC 61000-4-5 ELECTRICAL Model Single or Three-phase Voltage Current** per phase E4551A/E4551kV* Single-phase 250V rms 15/16A*** E4552A/E4552kV* Single-phase 277V rms 32A E4553A/E4553kV* Three-phase 480V rms 16A E4554A/E4554kV* Three-phase 480V rms 32A E4555 Three-phase 600V rms 50A E4556 Three-phase 600V rms 100A * kV version is required for operation with surge modules greater than 7kV, such as the E510A. All standard coupler/decoupler options apply ** Actual current capability may be limited by the AC line connectors selected *** Depends on connector selected. Typically 15A with U.S. NEMA connector; 16A with appropriate European style connectors Coupling Mode Coupling mode selection is controlled manually from the control selection center, or automatically using KeyTek SurgeWare¢â or BurstWare¢â software. Coupling is allowed from any line to any other line or combination of lines. Monitoring Monitoring and peak detection of surge voltage across any two manually-selected lines. Monitoring can be at the EUT or at the front panel of the coupler/decoupler. COMBINED SURGE & EFT COUPLER/DECOUPLERS Monitoring and peak detection of surge current in either High or Neutral, selected by the ECAT Control Center or the computer, measured without including back-filter surge current. Minimum E100 series control center EFT or mains - coupled surge module Requirements Options E455x-DC Allows the E455x coupler/decoupler to be used with DC as well as AC mains. The DC current ratings for essentially resistive loads are: to 48V to 110 V to 220V E4551A/E4551kV 15A 5A 0.8A E4552A/E4552kV 15A 5A 0.8A E4553A/E4553kV 20A 8A 1.2A E4554A/E4554kV 25A 8A 1.2A E4555 50A 50A (120V) 30A E4556 100A 50A (120V) 30A E455x-VI Enhanced V and I monitoring. Adds monitoring and peak detection of surge voltage and current. Upper and lower limits can be placed on surge peaks. Monitoring of 3 wires is provided in single-phase systems, 5 wires in three-phase systems. Selection of the V and I inputs is performed from the control center or can be made automatically with SurgeWare control software E455x-HV Increases the AC mains voltage rating from 277V to 480V rms in the E4552, and from 480V to 600V rms in the E4553 and E4554. The HV option is not available in the E4551, E4555 and E4556. Physical Physical size of module varies depending on model number

 
 