Model
LSS-15AX SERIES
°³¿ä
LSS-15AX Series´Â IEC pub. 61000-4-5 ±Ô°Ý ½ÃÇè»Ó¸¸ ¾Æ´Ï¶ó ±×º¸´Ù ³ôÀº ½ÃÇè±îÁöµµ ¿ÏÀüÇÏ°Ô ½ÃÇèÇÒ ¼ö ÀÖµµ·Ï »õ·Ó°Ô ¼³°è µÇ¾úÀ¸¸ç, ½ÃÇè±âÀÇ ±¸¼ºÀº open- circuit 1.2/50§Á Àü¾ÐÆÄÇü°ú short-circuit 8/20§Á Àü·ùÆÄÇüÀ» ¹ß»ý½ÃÅ°´Â (Combination) Wave ¹ß»ýºÎ¿Í CCITT 10/700§Á Telecom Wave ¹ß»ýºÎ, 0.5us-100kHz ¹ß»ý½ÃÅ°´Â (Ring) Wave ¹ß»ýºÎ ¹× CDNÀ¸·Î µÇ¾î ÀÖ´Ù.
¶ÇÇÑ Surge Ãâ·Â Àü¾ÐÀÌ 15KV±îÁö ¹ß»ýµÇ±â ¶§¹®¿¡ ÇǽÃÇèü¿¡ ´ëÇÑ ÇÑ°è½ÃÇè°ú Æı«½ÃÇè±îÁöµµ ½ÇÇà ÇÒ ¼ö ÀÖ´Ù.
Ư¡
Ãâ·Â Àü¾ÐÀÌ 15KVÀÇ ´ëÃâ·ÂÀ̹ǷΠÁ¾·¡¿¡ ÇàÇØ¿Ô´ø ·Ú Surge Impulse¿¡ ÀÇÇÑ Àý¿¬³»·Â ½ÃÇèµµ ÀÚµ¿À¸·Î ½ÇÇà ÇÒ ¼ö ÀÖ´Ù.
¼³°è, °³¹ß ºÎ¹®¿¡¼ Áß½ÃµÈ manual½ÃÇè°ú Ç°Áú°ü¸® ºÎ¹®, Test Siteµî¿¡¼ Á߽õǴ programÀ» ÀÌ¿ëÇÑ Æò°¡½ÃÇè ¸ðµÎ¸¦ º¸´Ù È¿À²ÀûÀ¸·Î °£´ÜÈ÷ ½ÃÇèÇÒ ¼ö ÀÖµµ·Ï Á¶ÀÛ panelÀÌ °³·® µÇ¾ú´Ù.
Á¶ÀÛ panel¿¡ Alarm lamp¿Í Emergency stop buttonÀÌ ºÎÂøµÇ¾ú°í, ÇöÀç ½ÃÇè ½ÇÇàÁß
ÀÎÁö¸¦ ÇÑ´«¿¡ º¼ ¼ö ÀÖµµ·Ï ÇÏ¿© ¾ÈÁ¤¼ºÀ» ´õ¿í Áß¿ä½ÃÇؼ ¼³°èµÇ¾úÀ¸¸ç, Á¶ÀÛ panel°ú µ¿ÀÏÇÑ ±â´ÉÀ» °®Ãá ¸®¸ðÄÜÀ» ÀÌ¿ëÇÏ¿© ½ÃÇèÇÒ ¼ö ÀÖ´Ù.
Àü¿ø Line ÁßøºÎ(CDN)´Â standard modelÀÎ °æ¿ì ÃÖ´ë 3»ó AC 600V/50AÀÌ°í, »ç¿ëÀÚÀÇ ¿ä±¸¿¡ ÀÇÇÏ¿© Ư¼ö Á¦ÀÛµµ °¡´ÉÇÏ´Ù.
Option
INFRA-REDREMOTE CONTROLLER, 08-00006B
MEMORY CARD, 08-00003A
WARNING LAMP, 11-00008A
CONNECTING TERMINAL BASE 30A, 18-00048B
CONNECTING TERMINAL BASE 50A, 18-00058B
WAVEFORM CHECK TERMINAL BNC, 02-00023A
Spec
Items / Models
LSS-15AX A1A
LSS-15AX A3A
LSS-15AX C1A
LSS-15AX C3A
Surge generating unit
Output waveform
Open circuit voltage (short circuit current)
1.2/50§Á (8/20§Á)
¨ç1.2/50§Á(8/20§Á)
¨è10/700§Á(5/320§Á)
Output voltage / current
15kv/7500A
¨ç15kv/7500A(1.2/50§Á)
¨è15kv/375A (10/700§Á, at output 40§Ù
Surge switching element
By lgnitron
Output polarity
Positive or negative
Surge repetition cycle
20 sec
¨ç20 sec. (1.2/50§Á)
¨è30 sec. (10/700§Á)
Output impedance
2§Ù
¨ç2§Ù (1.2/50§Á)
¨è40§Ù (10/700§Á with limiter resister)
AC/DC lines CDN
Injecting surge waveform
1.2/50§Á
Injecting surge voltage / current
15kv/7500A maximum
Surge coupling
Between line and line:18§Þ Between line and PE:10§Ù+9§Þ
AC Power capacity
Single phase, AC240V/30A (LSS-15AX A1A/C1A)
Single phase/3-phase, AC600V/50A (LSS-15AX A3A/C3A)
Voltage drop
9V at 25A, 11V at 30A, 18V at 50A
DC Power capacity
DC60V/20A
Decoupling coil
1.5mH (each phase)
Decoupling capacitor
10§Þ(Between line and line, betweenline and PE)
Coupling phase angle control
0 ~ 360¨¬ (at 1¨¬ step)
Residual voltage
<15% of test voltage or twice of rated voltages (peak) of EUT
Communication lines CDN
Injecting surge waveform
1.2/50§Á
10/700§Á
Injecting surge voltage
15kv max.
Matching resistance
40§Ù (1.2/50§Á)
25§Ù (10/700§Á)
Total line number
4 lines
Decoupling coil
20mH (each phaes)
Power capacity of EUT
DC50V 100mA
Voltage / current
monitor output
Voltage /
current monitor output ratio
1/2000 (voltage monitor), 1000A/V (current monitor)
Check circuit method
Waveform measuring method by magnetic coupling
Auto control functions
Surge generating unit
. Polarity selection
. Surge output port selection
. Surge waveform selection
. Polarity selection
. Output port selection
. 10/700§Á limiter resister selection
AC/DC lines CDN
. Surge injection line selection
. Surge return line selection
. Coupling element selection
Communication lines CDN
. Matching resistance selection
. 2 lines / 4lines selection
. Surge return line selection
Application function
Operation mode
1) Manual test mode 2)Program test mode
Voltage /
Current monitor function
1) Peak level display 2)Break down detecting
External interface
Communication function
RS-232C (Optional), GP-IB (Optional)
Power supply
AC90 ~ 120/200 ~ 240V 450VA 50/60Hz
Dimensions (W) x (H) x (D) mm
555 X 1250 X 790 (A1A)
555 X 1500 X 790 (A3A)
555 X 1500 X 790 (C1A)
555 X 1800 X 790 (C3A)
Weight
Approx. 200kgs (A1A)
Approx. 200kgs (A3A)
Approx. 270kgs (C1A)
Approx. 270kgs (C3A)
Items / Models
LSS-15AX B1RB
LSS-15AX B3R-G583
Output surge waveform
1.2/50ms, 8/20ms (Combination waveform)
0.5ms-100kHz (Ring wave)
Maximum output voltage
(current)
15kV/7500A (Combination wave)
12kV/1000A (Ring wave)
Output polarity
Positive or negative
Surge switching element
By ignitron
Surge repeat cycle
20 seconds (Combination wave: at 15kV)
10 seconds (Ring wave: at 12kV)
Output impedance
2 §Ù (Combination wave)
12 §Ù (Ring wave: when current limiting 500A is selected.)
30 §Ù (Ring wave: when current limiting 200A is selected.)
Injection surge waveform
Combination waveform
0.5§Á-100kHz Ring wave
Maximum injection surge
voltage (current)
15kV/ 7500A(Combination wave)
12kV/1000A (Ring wave)
Surge coupling
Normal mode: 18 §Þ, Common mode: 10§Ù +9§Þ
Coupling Mode
L1-PE, L2-PE, L1-L2, L2-L1
L1-PE, L2-PE, L3-PE, N-PE, L1-L2,
L1-L3, L1-N, L2-L1, L2-L3, L2-N,
L3-L1, L3-L2, L3-N, N-L1, N-L2,N-L3
Injection AC power capacity
Single phase AC240V/30A max
Single/3-phase AC600V/50A max
Injection DC power capacity
DC60V / 20A
Decoupling coil
1.5mH (Each phase)
Decoupling condenser
10§Þ (Between lines, Between line and PE)
Phase angle control
0¢ª~360¢ª (At step of 1¢ª)
Check circuit output ratio
1/2000 (V¡¤MON), 1/1000A (A¡¤MON)
Type of check circuit
Waveform measuring system using magnetic coupling
Surge generating unit
Surge waveform change
Current limiting change
Polarity change
Surge output change
AC/DC injection unit
Surge injection phase change
Surge return phase change
Coupling element change
Memory card (Option)
SRAM Memory card of JEIDA V4.1 (less than 1MB) can be used.
For DOS file format
Remote control (Option)
32 key infrared light remote control, Battery: UM-4 2 pcs.
Test mode
Manual test mode
Program test mode
Waveform monitor
Peak level indication
Break-down indication
Power supply
AC90~120 200~240V 450VA
Dimensions
555 (W) x 1250 (H) x 790 (D) mm
Model
Output waveform
AC/DC power line CDN
Telecom line CDN
1.2/50§Á+8/20§Á
Combination wave
CCITT 10/700§Á
Telecom wave
Single phase
AC240V/30A
DC60V/20A
Single and 3-phase
AC600V/50A
DC60V/20A
DC50V/10mA
A-1
¡Ü
¡Ü
A-3
¡Ü
¡Ü
B-1
¡Ü
¡Ü
¡Ü
B-3
¡Ü
¡Ü
¡Ü
C-1
¡Ü
¡Ü
¡Ü
¡Ü
C-3
¡Ü
¡Ü
¡Ü
¡Ü
»ç¾÷ÀÚµî·Ï¹øÈ£ 113-01-57596| ¼¿ï½Ã ±¸·Î±¸ ±¸·Îº»µ¿1258 Áß¾ÓÀ¯Åë´ÜÁö °¡µ¿ 2413È£ Åë½ÅÆǸŠÁ¦ 1918È£ | ´ëÇ¥ÀÚ¸í ±èâ¼ö
ÀÎâ°èÃø±â
ÀüÈ 02-2616-4851 Æѽº 02-2616-4852
Copyright
ÀÎâ°èÃø±â
2008 All rights reserved.
²ô±â