:::ÇöÀçÀ§Ä¡ HOME ¢º Áß°íÁ¦Ç° ¢º EMC EMI °ü·Ã±â±â(ÀÓÆÞ½º³ëÀÌÁî/½áÁöÁ¦³Ê·¹ÀÌÅÍ/Á¤Àü±â¹ß»ý±â) ¢º Impulse Noise Simulator ¢º INS-4020 Impulse Noise
    
Ãßõ»óÇ°
 
 
INS-4020 Impulse Noise
 
 
IMPULSE NOISE SIMULATOR
 
   Model
  • INS-4020 / 4040 (2KV Type / 4KV Type)
 
   °³¿ä
  • ´Ù¾çÇÑ Àü±âÀüÀÚ ±â±âµéÀÇ Noise¿Í °ü·ÃµÈ ¿Àµ¿ÀÛÀº ÇöÀç ½É°¢ÇÑ »çȸÀûÀÎ ¹®Á¦°¡ µÇ¾úÀ¸¸ç, Noise¿¡ ´ëÇÑ ³»¼ºÀÌ °áÇÌµÈ ±â±âµéÀº ¼öÃâÀÔ¿¡ À־ Á¦ÇÑÀ» ¹Þ´Â ½ÇÁ¤ÀÌ´Ù. À¯µµºÎÇÏÀÇ ´ÜÀýÀ̳ª Relay°¡ on/offµÉ ¶§ ¹ß»ýµÇ´Â ±â±â ¿Àµ¿ÀÛÀÇ Áß¿ä ¿øÀÎÁß ÇϳªÀÎ ½ºÀ§Ä¡¼º °úµµÀü¾Ð°ú °°Àº noiseµéÀÇ ÁÖÆļö ¹üÀ§´Â ±²ÀåÈ÷ ³Ð¾î¼­ GHz´ë¿ªÀÇ ÁÖÆļö¸¦ Æ÷ÇÔÇÏ°í Àֱ⠶§¹®¿¡ ±¤´ë¿ªÇÑ ÀâÀ½À» ¹ß»ý½ÃÅ°´Â Impulse noise ½ÃÇè±â·Î simulationÇÒ ÇÊ¿ä°¡ ÀÖ´Ù.
    ÀÌ·¯ÇÑ ÀÌÀ¯·Î ¹Ì±¹ ¹× ÀϺ»¿¡¼­´Â ¿À·¡ÀüºÎÅÍ ÀüÁÖÆļö ´ë¿ª¿¡ ¹ÌÄ¡´Â noise¸¦ ÇÑ ¹ø¿¡ Àΰ¡ÇÏ¿© °íÁÖÆÄ¿¡ ´ëÇÑ immunity¸¦ ½ÃÇè ÇÒ ¼ö ÀÖ´Â Impulse noise ½ÃÇè±â°¡ »ç¿ëµÇ¾îÁ³´Ù
 
   Ư¡
  • PulseÀÇ rise timeÀÌ °í¼ÓÀ¸·Î »ó½ÂÇÏ´Â 1nsÀÌÇÏ ÀÌ°í, ±¤´ë¿ªÇÑ ÁÖÆļö ¼ººÐÀ» Æ÷ÇÔÇϱ⠶§¹®¿¡ noise Æò°¡ ½ÃÇè±â·Î¼­´Â ÃÖ´ëÀÇ È¿°ú¸¦ ¾òÀ» ¼ö ÀÖ´Ù.
  • PulseÆøÀ» 50ns¡­1,000ns±îÁö, 50ns °£°ÝÀ¸·Î °¡º¯ °¡´ÉÇϹǷÎ, spectrumÀÌ ¾ø´Â ºÎºÐÀÌ »óÈ£ º¸¿ÏµÇ¾î Àü ÁÖÆļö´ë¿ªÀÇ ÀâÀ½À» Àΰ¡ ÇÒ ¼ö ÀÖ´Ù.
  • Ãâ·Â Àü¾ÐÀ» 4KV±îÁö ¿Ã¸± °æ¿ì, »ê¾÷¿ë ±â±âÀÇ noise½ÃÇè¿¡ ÃÖÀûÀÌ´Ù.
  • Àü¿ø LineÀÇ ÀÓÀÇÀÇ À§»ó¿¡ noise¸¦ Àΰ¡ ÇÒ ¼ö ÀÖ°í, ¿ÜºÎÀÇ Trigger ½ÅÈ£¿¡ µ¿±âÇÏ¿© pulse¸¦ ¹ß»ýÇÏ´Â °ÍÀÌ °¡´ÉÇÏ´Ù.
 
   Option
  • Injection Unit, IJ-4050
  • Outlet Panel (UL/JAPAN PLUG), 18-00059C
  • Outlet Panel (CCE7 Type/Schuko Plug), 18-00060B
  • Circuit Breaker, 18-00072A
  • Coupling Adapter, CA-803A / CA-805B / CA-806
  • Radiation Probe, 01-00006A ~ 10A
  • EMS Probe Kits, H2-B
  • Attenuator for Observation of Waveform, AT-810
  • Triangular wave unit, 02-00099A
 
   Spec
Parameters INS-4020 INS-4040
Output voltage 0.01~2.00kV ¡¾10% with 50¥Ø Load
(¡¾0.04kV for <0.1kV)
0.01~4.00kV ¡¾10% with 50¥Ø Load
(¡¾0.04kV for <0.1kV)
Polarity Positive or negative
Square
wave
Pulse width 50ns, 100ns, 200ns, 250ns, 400ns and any combination thereof, maximum width 1¥ìs , or 10ns¡¾3ns (the shortestconnection)
Rise time <1ns
Output impetance 50¥Ø system (53.5¥Ø)
Pulse
repetition
mode
PHASE 50 or 60Hz, Injection phase angle 0~359¡Æ(Synchronized with L1, L2 of power
supply to be injected, or external terminal.)
VARIABLE 10ms ~ 999ms ¡¾10% 16ms ~ 999ms ¡¾10%
EXT >10ms
TTL/Open collector negative logic
>16ms
TTL/Open collector negative logic
1 SHOT By trigger switch, a single pulse injection to any phase angle of the power line
Power capacity of EUT AC240V Single phase, DC60V, 16A
Power supply 100 ~ 240 VAC 50/60 Hz
Power consumption 140VA
Operating temperature and humidity 15 ~ 35¡É 25 ~ 75% (No dewing shall occur.)
Dimensions and weight (W)430 x (H)249 x (D)420 mm (Projections exluded) / Approx. 19 kg
 
 