½ÅÁ¦Ç°
Áß°íÁ¦Ç°
Àü±â¾ÈÀüÀåºñ
ESCOµî·ÏÀåºñ, ¿¡³ÊÁöÁø´ÜÀåºñ
½ÅÀç»ý¿¡³ÊÁö°ü·ÃÀåºñ
Á÷Á¢»ý»ê °Ë»ç¼³ºñ(¹ýÁ¤¼³ºñ)
write_poem
°øÁö»çÇ×
°í°´ °Ô½ÃÆÇ
Á÷°Å·¡ ÀåÅÍ
°í°´ ÀÚ·á½Ç
±¸¸Å|¸Å°¢ A/SÀÇ·Ú
 

  ¢Ï  °í°´¼¾ÅÍ

 TEL: 02-2616-4851

 FAX: 02-2616-4852

 H.P:010-3778-0143

 mail:kcs465@naver.com   

 
 
:::ÇöÀçÀ§Ä¡ HOME ¢º Áß°íÁ¦Ç° ¢º EMC EMI °ü·Ã±â±â(ÀÓÆÞ½º³ëÀÌÁî/½áÁöÁ¦³Ê·¹ÀÌÅÍ/Á¤Àü±â¹ß»ý±â) ¢º Impulse Noise Simulator ¢º Fast Transient Burst Simulator/FNS-AX3-B50
    
Ãßõ»óÇ°
 
 
Fast Transient Burst Simulator/FNS-AX3-B50
 
 
Model
  • FNS-AX3-A16A / FNS-AX3-B50A
 

   °³¿ä

  • Àü±â ÀüÀÚÀåºñµéÀÇ ¿Àµ¿ÀÛÀº ½ºÀ§Ä¡¼º ³ëÀÌÁî¿Í °°Àº Àü±âÀûÀÎ ºü¸¥ °úµµÇö»ó¿¡ ÀÇÇØ ¹ß»ýµÇ¸ç, ÀÌ·¯ÇÑ ¿Àµ¿ÀÛÀÇ ¹®Á¦Á¡À» Á¦Ç°°³¹ß ½ÃÁ¡ºÎÅÍ °ËÅäÇÏ°Ô µÇ¾ú°í, ÇöÀç¿¡ À̸£·¯¼­´Â ±¹Á¦±Ô°ÝÀÎ IEC pub. 61000-4-4 (EN 61000-4-4)¿¡ ´ëÀÀÇÏ´Â FAST TRANSIENT NOISE¸¦ Àΰ¡ÇÔÀ¸·Î½á, ½ºÀ§Ä¡¼º ³ëÀÌÁî °ü·Ã Immunity½ÃÇèÀ» äÅÃÇÏ°í ÀÖ´Ù. FNS -AX Series´Â IEC ±Ô°Ý¿¡¼­ ¿ä±¸ÇÏ´Â ¹ÝµµÃ¼ Switch ¹æ½ÄÀ» äÅÃÇÏ¿´À¸¸ç, »ç¿ëÀÚÀÇ Á¶ÀÛ¼ºÀ» À§ÇÏ¿© Front PanelÀ» Touch Panel Color LCD¸¦ äÅÃÇÏ¿´À¸¸ç, ¿¬¼ÓProgramÀ» ¸¸µé¾î ÀÚµ¿ ½ÃÇèÀÌ °¡´ÉÇÏ´Ù.
 
   Ư¡
  • IEC±Ô°Ý¿¡¼­ ¿ä±¸ÇÏ´Â ¸ðµç ½ÃÇèÀÌ °¡´ÉÇÔÀº ¹°·Ð, Field¿¡¼­ÀÇ ¿Àµ¿ÀÛ ÀçÇöÀ̳ª ´ëÃ¥ ½ÃÇè±â·Î ±â´ÉÀ» Áß½ÃÇØ,
    10ºÐ ¿¬¼Ó PulseÀΰ¡½ÃÇè, ±Ø¼º ÀÚµ¿¹ÝÀü ±â´É ¹× Pulse ÁÖÆļö º¯Á¶ ±â´ÉµîÀ» äÅÃÇÏ¿© Field¿¡¼­ÀÇ ¹®Á¦Á¡¿¡
    Á» ´õ Á¢±ÙÇÏ¿© ½ÃÇè ÇÒ ¼ö ÀÖµµ·Ï ¼³°èµÇ¾î Á³´Ù.
  • IEC ±Ô°Ý¿¡¼­´Â ½ÃÇè±âÀÇ À§Ä¡¸¦ ¹Ù´ÚÀÇ Ground PlaneÀ§¿¡ ¿Ã·Á³õ°í »ç¿ëÇÏ°Ô µÇ¾î ÀÖ¾î, Stand TypeÀ¸·Î
    µðÀÚÀεǾú°í, Á¶ÀÛ¼ºÀÌ ¿ì¼öÇÏ¿© Àå½Ã°£ »ç¿ëÇصµ ºÒÆíÇÏÁö ¾Ê´Ù.
  • »ç¿ëÀÚ´Â °¢ ½ÃÇè Á¶°Ç¿¡ ¸Â´Â Manual Mode, Program Mode ¹× Remote Mode¸¦ »ç¿ëÇϸé ÀÚµ¿À¸·Î ½ÃÇèÀ»
    ½Ç½ÃÇÏ¿© ºü¸¥ ½Ã°£ ³»¿¡ ¼Õ½±°Ô ½ÃÇè °á°ú¸¦ ¾òÀ» ¼ö ÀÖ´Ù.
  • ½ÃÇèÁß ¾ÈÀüÀ» °í·ÁÇÏ¿© ±ä±Þ»çÅ ¹ß»ý½Ã¿¡ ºü¸¥ ´ëÀÀÀÌ °¡´ÉÅä·Ï ÇǽÃÇèüÀÇ Àü¿ø°ú º» ½ÃÇè±âÀÇ Ãâ·ÂÀ»
    µ¿½Ã¿¡ Á¤Áö½ÃÅ°´Â ºñ»óÁ¤Áö ½ºÀ§Ä¡°¡ ÀåÄ¡µÇ¾î ÀÖ´Ù.
  • °¢Á¾ Outlet Panel(Consent)ÀÌ ±¸ºñµÇ¾î ÀÖÀ¸¸ç, GP-IB ¶Ç´Â RS-232C¸¦ ÀÌ¿ëÇÑ ¿ÜºÎ¿ÍÀÇ Interfaceµµ
    °¡´ÉÇÏ´Ù.
 
   Option
  • Injection Unit (3Phase AC480V 150A), CDN-151
  • Coupling Clamp, 15-00001A
  • EMS Probe Kits, H2-B
  • Outlet Panel (Multi 250V/15A), 18-00077A
  • Attenuator for Observation of Waveform (50§Ù), AT-810
  • Attenuator for Observation of Waveform (1§Ú), AT-811
  • EFT ½ÃÇèȯ°æ¼³ºñ, FNS-801-D
 
   Spec
Items

FNS-AX3-A16

FNS-AX3-B50
Output voltage 200 to 4800V
Pulse parameters at 50 ohm Pulse rise time 5ns ¡¾30%, Pulse width 50ns ¡¾30%
Pulse parameters at 1k ohm Pulse rise time 5ns ¡¾30%, Pulse width 35ns ¡¾150%
Polarity Positive, Negative, Polarity change burst by burst
Pulse frequency 0.1§Õ to 2§Ö
Burst duration 1to 1000 pulses or continuous ¡Â 1 pulse per 1ms vurst period
Burst period 10 to 1000ms ¡¾10%, 10ms step
Continuous mode operation 10§Õ max (0.2 to 1§Ç)
Dynamic output impedance 50ohms
Output connector Coaxial (pulse out)
Coupling / DC blocking capacitor 33§Ý/10§Ý
Frequency modulation 0 to -10% of setting
Timer (test duration) 1s to 9h 59m 59s
10 minutes max in the "conuinuous" and alternate polarity modes
External trigger TTL down edge
Minimum trigger interval acceptable : 10ms
Burst timing Non-synchronization Irrespective of EUT mains frequency
Synchronization Synchronizes with the EUT mains frequency
0 to 360 degrees ¡¾10 degrees, 1 degree step
Burst period : 50/60§Ô
Internal CDN 85 to 240VAC 16A 50/60§Ô
3-wire single-phase
125V DC/16A
85 to 500VAC 50A 50/60§Ô
5-wire three-phase
125V DC/50A
Internal CDN L, N, PE L1, L2, L3, N, PE
Coupling mode Common mode
Dimensions (projection included) (W)320 ¡¿ (H)352¡¿ (D)400mm
Character display English, Chinese, Korean or Japanes
Weight Approx. 14§¸ Approx. 19§¸
 
 
»ç¾÷ÀÚµî·Ï¹øÈ£ 113-01-57596| ¼­¿ï½Ã ±¸·Î±¸ ±¸·Îº»µ¿1258 Áß¾ÓÀ¯Åë´ÜÁö °¡µ¿ 2413È£ Åë½ÅÆǸŠÁ¦ 1918È£ | ´ëÇ¥ÀÚ¸í ±èâ¼ö
ÀÎâ°èÃø±â ÀüÈ­ 02-2616-4851 Æѽº 02-2616-4852