Impulse Noise Simulator
¢º IMPULSE NOISE SIMULATOR INS-AX2-420
IMPULSE NOISE SIMULATOR INS-AX2-420
¢¹ °£´ÜÇÑ ¼³¸í
Á¦Á¶»ç : Noiseken
Á¦Á¶±¹ : ÀϺ»
ÁÖ¿ä»ç¾ç :
0.01 ~ 2.00kV / 4.00KV¡¾10% at 0.01kV step
(Pulse width) 50, 100, 200, 400, 500, 800, 1000ns ¡¾10%, 10ns¡¾3ns
GENERAL
The INS-AX2 series simulators are the advanced version of the conventional manually operated INS-4020/4040 simulators, maintaining the identical interference signal characteristics while offering a new level of ease of use.
FEATURES
An innovative,motor driven coaxial switch mechanism eliminates the need to manually plug and unplug coaxial connectors, allowing a preset test sequence to be carried out seamlessly including pulse width and coupling mode changes, automatic voltage ramp and others.
As well as manual control, the simulator can be remote-controlled through a fiber optic computer interface.
A Windows control software package
is supplied as an included accessory.
Floating output
8 pulse widths installed: 10ns, 50ns, 100ns, 200ns, 400ns, 500ns, 800ns and 1000ns
Internal switchable terminators
Easily changeable and safety-interlocked outlet panel (EUT interface)
3 channels EUT fail input
SPECIFICATIONS
Item
Model
INS-AX2-220/250
INS-AX2-420/450
Pulse output voltage
0.01 ~ 2.00kV¡¾10% at 0.01kV step
0.01 ~ 4.00kV¡¾10% at 0.01kV step
¡¾0.04kV allowance for <0.1kV setting
When the output is terminated by the internal resistors.
Output polarity
Positive or negative
Pulse
Pulse width
50, 100, 200, 400, 500, 800, 1000ns ¡¾10%, 10ns¡¾3ns
Rise time
<1ns
Output impedance
50 ohm
system (53.5 ohm)
Pulse repetition mode
Variable
10ms ~ 999ms¡¾10%
16ms ~ 999ms¡¾10%
Phase
Injection phase angle 0 to 360 degrees¡¾10 degrees
EUT power supply:>AC90V, 50/60Hz¡¾10%
1 shot
Single pulse generation, each time the 1 SHOT button is pressed.
Synchronized output with phase angle setting in PHASE mode
Power capacity of EUT
INS-AX2-220:
Single phase AC240V/DC65V 20A
INS-AX2-250:
3-phase (4-wire) AC500V/DC250V 50A
50/60Hz¡¾10%
NS-AX2-420:
Single phase C240V/DC65V 20A
INS-AX2-450:
3-phase (4-wire) AC500V/DC250V 50A
50/60Hz¡¾10%
Power supply
AC 100V~240V¡¾10%, 50/60Hz
¡¾10%
Power consumption
110VA
Operating temperature and humidity range
15 ~ 35¡ÆC
, 25 ~ 75% (No dewing shall occur.)
Dimensions
W 430 x H 350 x D 470mm
, projection excluded
Weight
INS-AX2-220: Approx. 30Kg
INS-AX2-250: Approx. 38Kg
INS-AX2-420: Approx. 30Kg
INS-AX2-450: Approx. 38Kg
Mercury relay unit
Model: 04-00014A
Model: 04-00015A
TRIANGULAR PULSE ADDITION (Factory Option)
Parameters
Specifications
Output pulse waveform
Triangular pulse
Pulse output voltage
2kV (220/250) and 4kV (420/450) max (when the output is terminated by the internal resistors)
Output polarity
Positive or negative
Pulse
Duration
1µs¡¾30%
Rise time
<40 ns
When the triangular pulse generator has been built-in, the original model numbers become INS-AX2-220T/420T/250T/450T with an affix of "T
".
STANDARD ACCESSORIES
INS-AX2-220/420
INS-AX2-250/450
Outlet panel (Single phase terminal block type) Model:18-00067A AC240VDV65V20A max
Outlet panel (3-phase terminal block type) Model:18-00068A AC500VDV250V50A max
Power cable
Remote control software (CD-ROM) Model: 14-00033A
Optical conversion adapter
Optical cable (5m)
D-sub conversion connector
Instruction manual (for the simulator and remote control software)
Notice: Either 18-00067A (For INS-AX2-220/INS-AX2-420) or 18-00068A (For INS-AX2-250/ INS-AX2-450) is mounted on the simulator at shipment.
Optional accessories for the INS-AX2 series
OUTLET PANEL MODEL: 18-00069A
OUTLET PANEL MODEL: 18-00070A
JP/USA type, AC125V 20A MAX
CEE7/Schuko type, AC240V 16A MAX
OUTLET PANEL MODEL: 18-00071A
CIRCUIT BREAKER BOX MODEL:18-00072A
Single phase AC240V20A 50/60Hz, DC65/20A
Multiple type, AC240V 15A MAX
CIRCUIT BREAKER BOX MODEL:18-00073A
3-phase AC415V50A 50/60Hz
MERCURY RELAY UNIT for replacement
MODEL: 04-00014A
for INS-AX2-220/250
MODEL: 04-00015A
for INS-AX2-420/450
OPTICAL INTERFACE BOX