DX200 DAQSTATION DX200 (4 ch) DAQSTATION DX200 (8 ch) DAQSTATION DX200 (10 ch) DAQSTATION DX200 (20 ch) DAQSTATION DX200 (30 ch) FDD CompactFlash memory card (CF+Adapter) 250 MB Zip (with medium) Alarm output 2 points/Remote control*1*2 Alarm output 4 points/Remote control*1*2 Alarm output 6 points*1 Alarm output 12 points*1 Alarm output 24 points*1*3 Batch function RS-232 interface (including Modbus Master/Slave protocol)*4*5 RS-422-A/485 interface (including Modbus Master/Slave protocol)*4*5 FOUNDATION Fieldbus*4*6 VGA video output Fail/memory end detection and output*3 Clamped input terminal Desktop type (without power code, screw type power terminal)*7 Desktop type (with power code)*8 Mathematical function (with report function) Cu10, Cu25 RTD input/3 legs isolated RTD 3 legs isolated RTD*9 24 VDC/AC power supply 24 VDC transmitter power supply (4 loops)*10 24 VDC transmitter power supply (8 loops)*11 Remote control DX204 DX208 DX210 DX220 DX230 External memory Display language Options -1 -3 -5 -2 /AR1 /AR2 /A3 /A4 /A5 /BT1 /C2 /C3 /CF1 /D5 /F1 /H2 /H5 /H5[ ] /M1 /N1 /N2 /P1 /TPS4 /TPS8 /R1 English/Germany/French, deg F & Summer/ winter time (with English DAQSTANDARD) *1 /AR1, /AR2, /A3, /A4, /A5 cannot be specified together. *2 If /AR1 or /AR2 is specified, /R1 cannot be specified. *3 If /A5 is specified, /F1 cannot be specified. *4 /C2, /C3, and /CF1 cannot be specified together. *5 In case that Modbus master function is utilized, /M1 must be specified. *6 In case that FOUNDATION Fieldbus (/CF1) is specified, /M1 must be specified together. *7 In case that 24 VDC/AC power supply (/P1) and desktop type are specified together, /H5 must be specified. /P1 and /H5[ ] cannot be specified together. *8 /H5[ ] *9 /N2 cannot be specified for DX204, DX208 *10 In case that /TPS4 is specified, /TPS8 or /A5 cannot be specified. *11 In case that /TPS8 is specified, /TPS4 or /A5 cannot be specified. In case that /TPS8 is specified, /F1 and /A4 cannot be specified together. D ................ Power cord UL, CSA st¡¯d F ................ Power cord VDE st¡¯d R ................ Power cord SAA st¡¯d J ................ Power cord BS st¡¯d H ................ Power cord GB st¡¯d Application Software Model DXA100-02 WX104/CD1 DXA310-021 DXA410-02 DXA410-04 WX101/CD1 WX81/CD1 Description DAQSTANDARD DAQEXPLORER DAQ-PharmBio DAQOPC(Basic) DAQOPC(Advanced) DAQLOGGER(1600 channels) DAQLOGGER Client(1600 channels) Operating System Windows 98/Me/NT4.0/2000/XP Windows 2000/XP Windows 98/Me/NT4.0/2000/XP Windows 2000/XP Windows 2000/XP Windows 2000/XP Windows 2000/XP Related Products Accessories DX100L DAQSTATION Special Housing Model Special housing model for advanced network functions ♦ Works with recorders with different panel cuts and depths than the standard DX100. ♦ Foxboro(SPEC200), Subject to change without notice. [Ed : 05/b] Copyright ©2000 Printed in Japan, 604(KP) YOKOGAWA
|
Spec ¹× Ư ¼º |
¡á |
DX230(30ch) |
¡á |
ȸé : 5.5/10.4ÀÎÄ¡ TFT Color LCD |
¡á |
ÀúÀå : º»Ã¼ÀúÀå + FDD/ATA Flash Memory |
¡á |
ÀÌ´õ³Ý ³×Æ®¿÷(PC¿¡¼ ÀúÀå ¹× ½Ç½Ã°£ ¸ð´ÏÅ͸µ) |
¡á |
ÃÖ´ë ÀúÀå ÁÖ±â : 125ms or 1s |
DX100/200 »ç¾ç | |
|
|
DX100 |
DX200 |
Environment |
Portable |
Desktop |
Channel Numbers |
2, 4, 6, 12 |
4, 8, 10, 20, 30 |
Input Types |
Voltage (20 mV to 20 V), thermocouple (R, S, B, K, E, J, T, N, W, L, U), RTD, DI |
Maximum Measurement Interval |
2, 4 ch Model: 125 ms 6, 12 ch Model: 1 s |
4, 8 ch Model: 125 ms 10, 20, 30 ch Model: 1 s
|
Removable storage medium |
3 options (3.5-inch floppy disk, Zip disk, PCMCIA ATA flash memory card) |
Display |
5.5-inch wide-viewing-angle color LCD display |
10.4-inch wide-viewing-angle color LCD display |
External Dimensions and Weight |
152(W)x180(H)x188(D), Approximately 4 kg |
294.6(W)x294.6(H)x220(D), Approximately 7 kg | Àå½Ã°£ µ¥ÀÌÅÍ ÀúÀå Email°ú À¥ ¸ð´ÏÅ͸µ ¾Õ¼± ³×Æ®¿öÅ© ±â´É | | |
|