:::ÇöÀçÀ§Ä¡ HOME ¢º Áß°íÁ¦Ç° ¢º Àü¿ø±â±â(AC/DC ÆÄ¿ö¼­ÇöóÀÌ/³»Àü¾Ð½ÃÇè±â/ÁÖÆļöº¯È¯±â/¼Ò½º¸ÞŸ) AC Voltage/Current Standa/½½¶óÀÌ´Ú½º ¢º AC Power Source(ÁÖÆļöº¯È¯±â) ¢º 1251RP AC Power Source 15-500hz, 1,250VA
    
Ãßõ»óÇ°
 
 
1251RP AC Power Source 15-500hz, 1,250VA
  ¢¹ °£´ÜÇÑ ¼³¸í
  ÀϹÝ
»ý»êÀÚ; Ķ¸®Æ÷´Ï¾Æ ÀνºÆ®·ç¸ÕÆ®
¸ðµ¨; 1251RP
Á¶°Ç; »ç¿ë ¹× ¿ì¼öÇÑ Á¶°Ç¿¡¼­
Á¦Ç° Á¦Ç°; 1251RP
 
 
 

Ķ¸®Æ÷´Ï¾Æ ÀνºÆ®·ç¸ÕÆ® 1251RP/IF



1251RP ÇÁ·Î±×·¡¹Ö °¡´ÉÇÑ AC ¼Ò½º´Â 1250 VAÀÇ Àü·Â ¼öÁØ¿¡¼­ °¡º¯ Àü¾Ð ¹× ÁÖÆļö°¡ ÇÊ¿äÇÑ ¹ü¿ë AC Àü·Â ¾ÖÇø®ÄÉÀ̼ǿ¡ ÀÌ»óÀûÀÔ´Ï´Ù. Àü¾Ð, ÁÖÆļö ¹× Àü·ù Á¦ÇÑÀ» ¼³Á¤ÇÏ´Â µ¥ »ç¿ëµÇ´Â °£´ÜÇÑ ³ëºê¸¦ »ç¿ëÇÏ¿© ÀÛ°í °¡º­¿î ÆÐÅ°Áö¿¡¼­ Àú·ÅÇÑ AC Àü·Â¿øÀ» Á¦°øÇÕ´Ï´Ù. ÀÌ °èÃø±â´Â Á¤¹Ð µðÁöÅÐ ½Ã³×¿þÀÌºê ¹ßÀü±â¸¦ »ç¿ëÇÏ¿© ³·Àº ¿Ö°î Ãâ·ÂÀ» »ý¼ºÇÕ´Ï´Ù. µà¾ó LCD Æǵ¶°ªÀº Àü¾Ð, Àü·ù Á¦ÇÑ ¹× ÁÖÆļö¿¡ ´ëÇÑ ÇÁ·Î±×·¡¹ÖµÈ ¼³Á¤À» ¸íÈ®ÇÏ°Ô Ç¥½ÃÇÕ´Ï´Ù. Ãâ·Â Àü·Â: 1250 VA Ãâ·Â Àü¾Ð: 0 ~ 135 Vrms; 0 ~ 270 Vrms ÇØ»óµµ: 0.1 V ÃÖ´ë rms Àü·ù: 6 ¹«±â; 3 ¹«±â ÃÖ´ë ÇÇÅ© Àü·ù: 27.6 A; 13.8 º¸È£: Àü·ù, ¿Âµµ ÃÊ°ú ¹× Àü¾Ð ÃÊ°ú

California Instruments 1251RP AC Power Source, 1250 VA, 1 Phase

*Contact Axiom Test Equipment to RENT this item* 

DESCRIPTION


For product quality test applications, the California Instruments 1251RP AC power source can be used to simulate line conditions found anywhere in the world. Universal, Power Factor Corrected (PFC) input allows these products to be used anywhere in the world to provide a convenient source of variable utility power for the testing and evaluation of domestic and commercial equipment. All common line voltage and frequency combinations are covered. Loads requiring up to 4.6 Arms at 230 Vrms with peak currents up to 12 A can be tested with the 1251RP AC power source.

    The low total harmonic distortion of the output makes the California Instruments 1251RP a suitable AC source for IEC 61000-3-2 Current Harmonics pre-compliance testing. In addition, the frequency range covers 500 Hz, making these products ideal for commercial and defense avionics applications. A built in current measurement function eliminates the need for an external current shunt or transformer.  For additional protection, a current limit function can be set from zero to the maximum current rating. The small form factor and low weight of the California Instruments 1251RP make them convenient to use in a variety of locations.

 

Specifications of the California Instruments 1251RP AC Power Source includes: 

AC Power1250VA
Voltage Low/High0-135V/0-270V
Frequency16-500Hz
Peak Current Low/High27.6A/13.8A
Power Factor>0.95 Typical




¡¤ Programmable Power, Low Cost Cost effective solution for wide range of AC power tests ¡¤ 800 VA or 1250 VA Output Power Capable of handling most single phase applications ¡¤ Front and Rear Outputs Connect load to front panel outlets or rear panel terminal block for maximum convenience ¡¤ 16 Hz to 500 Hz Frequency Range Utility and Avionics applications ¡¤ High Peak Current Capability Drives a wide variety of non-linear loads ¡¤ Remote Control Option IEEE-488 and RS232C Interface for automated test applications Program AC Power Worldwide Model 801RP / 1251RP


Parameter 801RP 1251RP Unit Controller Type Programmable Controls Digital Encoders Readout Voltage 4 digit LCD Freq. / Current 4 digit LCD Non Volatile Setups (with -IF option) 8 Output AC Power 800 1250 VA Voltage High range / Low Range 0 - 270 / 0 - 135 V (L-N) Accuracy @ 50/60 Hz ¡¾ 1 % FS @ 400 Hz ¡¾ 2 % FS Resolution 0.1 V Line & Load Regulation High V range ¡¾ 0.5 % FS Low V range ¡¾ 1 % FS Line Regulation 10 % Line change ¡¾ 0.1 % FS T.H.D. @ 50/60 Hz 0.5 typical % Output Noise < 0.1 typical V Frequency (specifications valid from 45 Hz to 500 Hz) Range 16 - 500 Hz Accuracy ¡¾ 0.02 % Resolution below 100 Hz 0.1 Hz above 100 Hz 1 Hz Current Steady State Current High V range 3.0 4.6 A rms Low V range 6.0 9.2 A rms Peak Current High V range 13.8 13.8 A peak (shorted output) Low V range 27.6 27.6 A peak Protection Current limit Mode Programmable trip level Output trips off (Output shut off) Resolution 0.1 A rms Over Temperature Output shut off Over Voltage Output shut off Input Line Voltage1 2 wire + GND 100 -240 V rms Maximum operating range 85 - 265 V rms Line Current (fused) < 15 A rms Line Frequency 47 - 63 Hz Holdup Time 20 m s Power Factor > 0.95 typical Isolation Input to Chassis 1350 V Input to Output 2200 V Measurements Current (RMS steady state) Range 0.0 - 10.0 A rms Accuracy ¡¾ 0.2 A rms Resolution 0.1 A Voltage Range 0 - 278 V Resolution 1 (below 250 V) V Remote Control Option Interface types option -IF RS232C IEEE-488 IEEE-488 Address 0 - 31 IEEE Functions SH1, AH1, T8, L3, RL2, SRQ0, PP0 RS232C settings 9600,8,n,1 Command Language SCPI Physical Regulatory CE Dimensions HxWxD 3.5 x 16.8 x 22 inches HxWxD 89 x 427 x 560 m m Weight (net) 34 / 15.4 lbs / kg Vibration and Shock Designed to meet NSTA-1A Temperature Operating 0 to 40 / - 40 to + 85 ¡Æ C 1 120 Vrms minimum line input required for full 1250 VA output on model 1251RP. Note: Specifications are warranted for an ambient temperature of 23¡Æ + 5¡Æ C and apply after a 30 minute warmup period

 
 