:::ÇöÀçÀ§Ä¡ HOME ¢º Áß°íÁ¦Ç° ¢º Àü¿ø±â±â(AC/DC ÆÄ¿ö¼­ÇöóÀÌ/³»Àü¾Ð½ÃÇè±â/ÁÖÆļöº¯È¯±â/¼Ò½º¸ÞŸ) AC Voltage/Current Standa/½½¶óÀÌ´Ú½º ¢º AC Power Source(ÁÖÆļöº¯È¯±â) ¢º AC Power Source(ÁÖÆļöº¯È¯±â) VFC-1003 (3KVA)´Ü»ó/Áß°í
    
 
 
AC Power Source(ÁÖÆļöº¯È¯±â) VFC-1003 (3KVA)´Ü»ó/Áß°í
 
 




»ó¿ë ±³·ù Àü¿øÀ» ¼öÀüÇÏ¿© °í°´ÀÌ ¿øÇÏ´Â Ãâ·ÂÀü¾Ð ( 0 ~ 300V   *Option:0 ~ 700 V ) °ú
Ãâ·Â ÁÖÆļö ( 50, 60,400, 40 ~ 999 HZ . * Option : 40 ~ 5000 Hz ) ¸¦ ¾òÀ» ¼ö ÀÖ´Â
Àü¾Ð, ÁÖÆļö °¡º¯ÀåÄ¡( AC POWER SOURCE ) ÀÔ´Ï´Ù.

¼¼°è °¢ ³ª¶ó¸¶´Ù Àü¾Ð°ú ÁÖÆļö°¡ ´Ù¸£±â ¶§¹®¿¡ ¼öÃâÇÏ´Â Á¦Ç°ÀÇ °³¹ß ,°Ë»ç, »ý»ê ½Ã Ç°ÁúÀ» º¸ÁõÇϱ⿡
¾î·Á¿òÀÌ ¸¹¾Ò½À´Ï´Ù.
±×·¯³ª ÀÌÁ¦´Â ¼öÃâ Á¦Ç° °Ë»ç¿¡µµ , Á¦Ç° °³¹ß ½Ã¿¡µµ ¹®Á¦°¡ ¾ø½À´Ï´Ù.

º» ÀåÄ¡´Â  ower. Amplifier .Modulaton (Àü·Â ÁõÆø ¹æ½Ä) TYPEÀÇ ½Ã½ºÅÛ À¸·Î Ãâ·ÂÁÖÆļö¸¦ 50,60,400,40~999Hz±îÁö °¡º¯½Ãų ¼ö ÀÖÀ¸¸ç (option:10~5000Hz)±îÁö 40~99.9Hz±îÁö´Â 0.1Hz step °¡º¯Çϸç , 100~999Hz´Â 1Hz stepÀ¸·Î ¿øÇÏ´Â ÁÖÆļö¸¦ °¡º¯ ÇÕ´Ï´Ù. °¡º¯µÈ ÁÖÆļö¸¦ Ãâ·ÂÀü¾Ð 0~300V±îÁö(option:0~700V) VariableÇÏ¿© °ø±ÞÇÒ ¼ö ÀÖ´Â ½Ã½ºÅÛÀÔ´Ï´Ù. ÆÄÇü ¿ÖÀ²ÀÌ ÀÛ°í ( T.H.D :¡Â 1%) Ãâ·Â Àü¾Ð
¾ÈÁ¤µµ°¡ ¸Å¿ì ¿ì¼öÇϸç,  Ãâ·Â Àü¾Ð °¡º¯ ( 0 ~ 300V )¹æ½ÄÀÌ  " ¹ÝµµÃ¼°¡º¯ " ŸÀÔÀ̸ç Ãâ·ÂÀü¾Ð ¾ÈÁ¤µµ´Â ¡¾0.2% À̳»·Î ±¹³» Ÿ»çÀÇ " SLIDAC " ŸÀÔÀÇ Àü¾Ð°¡º¯ ¹æ½Ä¿¡¼­ ¹ß»ýÇÏ´Â ÀÔ·Â Àü¾Ð º¯µ¿ ½Ã ¶Ç´Â Ãâ·Â ºÎÇÏ(LOAD) Àΰ¡ ½Ã ¼³Á¤Àü¾ÐÀÌ 10 % ÀÌ»ó º¯µ¿ µÇ´Â ºÒ¾ÈÁ¤À» Çõ½ÅÀûÀ¸·Î ´ëÄ¡ÇÑ Á¦Ç°ÀÔ´Ï´Ù.

 

  • P.A.M(Power Amplifier Modulation)
  • CPU Á¦¾î¹æ½Ä
  • Digital Control ¹æ½Ä
  • Remoted Control °¡´É(RS-232C) *option
  • Ãâ·Â ÁÖÆļö ¾ÈÁ¤µµ ¡¾0.01%
  • 1% ¹Ì¸¸ÀÇ Distortion
  • TOTAL POWER °³³äÀÇ °úºÎÇÏ º¸È£±â´É
  • ºÎÇÏ Á¶°Ç¿¡ Á¦¾à¹ÞÁö ¾ÊÀº ½Å·Ú¼º

  • Motor Testing
  • Air Conditioner Testing
  • Power Supply testing
  • General Laboratory
  • Transformer Testing
  • Magnetic Testing
  • Reliability Testing
  • Standard AC SOURCE

±¸ºÐ

Ư¼º

Circuit Type

P.A.M (Power Amplifier Modulation)

Phase

1PHASE or 3PHASE (¡¾10%)

Input Voltage

100V / 110V / 115V / 120V / 200V / 230V / 240V / 380V / 440V

Input Frequency

50§Ô / 60§Ô

Output Voltage

1PHASE (0~300V) or 3PHASE (0~500,600,700V)

Voltage Stability

¡Â ¡¾0.2%

Output Frequency

50,60,400,40~999§Ô (option : 10~5000§Ô)

Frequency Stability

¡Â ¡¾0.01%

T.H.D

¡Â 1%

Protector

Electronic Circuit / Over Load / Short Ciruit

Frequency Meter

LED Digital Display Res 0.1§Ô

V.A-Meter

True RMS LED Digital Display

Temperature

0~40¡É

Humidity

0~90%

Output Wave

True sine Wave

Option

Output Voltage : 0~700V or Èñ¸ÁÀü¾Ð °¡´É
Output Frequency 10~5000§Ô
RS-232C Remote Control

 

¸ðµ¨¸í(´Ü»ó)

¿ë·®

¸ðµ¨¸í(´Ü»ó)

¿ë·®

VCFC-1001

1 KVA

VCFC-1015

15 KVA

VCFC-1002

2 KVA

VCFC-1020

20 KVA

VCFC-1003

3 KVA

VCFC-1030

30 KVA

VCFC-1005

5 KVA

VCFC-1050

50 KVA

VCFC-1007

7.5 KVA

VCFC-1075

75 KVA

VCFC-1010

10 KVA

VCFC-1100

100 KVA

 

¸ðµ¨¸í(»ï»ó)

¿ë·®

¸ðµ¨¸í(»ï»ó)

¿ë·®

VCFC-3001

1 KVA

VCFC-3015

15 KVA

VCFC-3002

2 KVA

VCFC-3020

20 KVA

VCFC-3003

3 KVA

VCFC-3030

30 KVA

VCFC-3005

5 KVA

VCFC-3050

50 KVA

VCFC-3007

7.5 KVA

VCFC-3075

75 KVA

VCFC-3010

10 KVA

VCFC-3100

100 KVA

 
 