½ÅÁ¦Ç°
Áß°íÁ¦Ç°
Àü±â¾ÈÀüÀåºñ
ESCOµî·ÏÀåºñ, ¿¡³ÊÁöÁø´ÜÀåºñ
½ÅÀç»ý¿¡³ÊÁö°ü·ÃÀåºñ
Á÷Á¢»ý»ê °Ë»ç¼³ºñ(¹ýÁ¤¼³ºñ)
write_poem
°øÁö»çÇ×
°í°´ °Ô½ÃÆÇ
Á÷°Å·¡ ÀåÅÍ
°í°´ ÀÚ·á½Ç
±¸¸Å|¸Å°¢ A/SÀÇ·Ú
 

  ¢Ï  °í°´¼¾ÅÍ

 TEL: 02-2616-4851

 FAX: 02-2616-4852

 H.P:010-3778-0143

 mail:kcs465@naver.com   

 
 
:::ÇöÀçÀ§Ä¡ HOME ¢º Áß°íÁ¦Ç° ¢º Àü¿ø±â±â(AC/DC ÆÄ¿ö¼­ÇöóÀÌ/³»Àü¾Ð½ÃÇè±â/ÁÖÆļöº¯È¯±â/¼Ò½º¸ÞŸ) AC Voltage/Current Standa/½½¶óÀÌ´Ú½º ¢º ³»¾Ð Àý¿¬ ÃøÁ¤±â ¢º 7440 Áß°í AC/DC/µµÅë/IR ³»Àü¾Ð½ÃÇè±â+Àý¿¬³»·Â½ÃÇè±â
    
 
 
7440 Áß°í AC/DC/µµÅë/IR ³»Àü¾Ð½ÃÇè±â+Àý¿¬³»·Â½ÃÇè±â
 
 
 
Ç°   ¸í  ³»Àü¾Ð½ÃÇè±â+Àý¿¬³»·Â½ÃÇè±â
 ¸ð   µ¨  7430
 Á¦Á¶»ç EXTECH
 Ãâ·ÂÀü¾Ð 5KV
 ÀÔ·ÂÀü¾Ð  220V

7400 series 500VA Electrical Safety Compliance Analyzers
7400 ½Ã¸®Áî Áß 500VAÀÇ ¿ë·®À¸·Î 200mAÀÇ Trip current¸¦ È®ÀÎ ÇÏ½Ç ¼ö ÀÖÀ¸¸ç 7400½Ã¸®Áî°¡ °¡Áö°í ÀÖ´Â ´Ù¾çÇÑ Å×½ºÆ®¸¦ ÇÏ½Ç ¼ö ÀÖ½À´Ï´Ù.
Ư¡
1. AC Output 500VA/100mA capacity
2. Short circuit current > 200mA
3. AC/DC Withstanding Voltage (ACW and DCW)/ Insulation Resistance (IR)/ Ground Bond (GND) tests
4. Single 20 x 2 LCD Display
5. Optional built-in 4 channels or 8 channels Scanner (7420, 7430 & 7440)
6. 50°³ÀÇ ¸Þ¸ð¸®¿Í ¸Þ¸ð¸®´ç 30°³ÀÇ ½ºÅÜ ÀúÀå °¡´É
7. Auto Offset, GB Test
8. Front panel software calibration
9. Built-in PLC Remote interface
10. Front Panel Lockout
11. GPIB (IEEE-488), RS232 or printer interfaces control
12. Line and load regulation maintains the output voltage within 1% of setting
 
Model       ALL
7410 7412 7420 7430 7440
SPECIFICATIONS
MODEL
7410
7412
7420
7430
7440
AC WITHSTAND VOLTAGE
Output Rating
5KVAC/30mA
5KVAC/20mA
5KVAC/30mA
5KVAC/40mA
5KVAC/40mA
 
Range
Resolution
Accuracy
Output Voltage,ACV
0 - 5000
1
¡¾£¨2% of setting + 5V£©
Output Frequency 50Hz/60Hz ¡¾100ppm, User Selection
Output Waveform Sine Wave ,THD.<2% (Resistive Load), Crest Factor = 1.3 - 1.5
Output Regulation ¡¾ (1% of output + 5V), From no load to full load
SETTINGS
Hi-Limit AC Current, mA
0-30.00
0-20.00
0-30.00
0-40.00
0-40.00
Resolution : 0.01, Accuracy : ¡¾£¨2% of setting + 3counts£©
Lo-Limit AC Current, mA Range : 0 - 9.999
Resolution : 0.001, Accuracy : ¡¾£¨2% of setting + 3counts£©
Ramp Time, second
0.1 - 999.9
0.1
¡¾£¨0.1% + 0.05sec£©
Dwell Time, second
0, 0.3 - 999.9
(0=continuous)
0.1
Arc Detection 1 - 9 ranges (9 is the most sensitivity)
AC Current Offset, mA 0 - 2.000 or Auto Set
DC WITHSTAND VOLTAGE
Output Rating 6KVDC/9999?A
Output Voltage, DCV
0 - 6000
1
¡¾£¨2% of setting + 5V£©
Output Ripple <5%£¨6KV/9999µA at Resistive Load£©
SETTINGS
Hi-Limit DC Current, µA
0 - 9999
1
¡¾£¨2% of setting + 3counts£©
Lo-Limit DC Current, µA
0 - 999.9
0.1
¡¾£¨2% of setting + 3counts£©
Ramp Time, second
0.1 - 999.9
0.1
¡¾£¨0.1% + 0.05sec£©
Dwell Time, second
0, 0.4 - 999.9
(0=continuous)
0.1
Arc Detection 1 - 9 ranges (9 is the most sensitivity)
DC Current Offset, ?A 0 - 200.0 or Auto Set
Ramp High Current ON/OFF, User Selection
Charge - Low Current, µA 0 - 350.0 or Auto Set
Discharge Time < 200 msec
INSULATION RESISTANCE
Output Rating 1KVDC/9999M¥Ø
Output Voltage, DCV
100 - 1000
1
¡¾£¨2% of setting + 3V£©
Hi-Limit Resistance, M¥Ø
0, 1 - 9999 (0=OFF)
1
¡¾£¨2% of setting+2counts£©at 500-1000VDC, 1 -1000 M¥Ø
¡¾£¨8% of setting+2counts£©at 500-1000VDC, 1000 -9999 M¥Ø
¡¾£¨8% of setting+2counts£©at 100-500VDC, 1 -1000 M¥Ø
Lo-Limit Resistance, M¥Ø
1 - 9999
1
Delay Time, second
0, 0.5 - 999.9
(0=continuous)
0.1
¡¾£¨0.1% + 0.05sec£©
Charge - Low Current, µA 0 - 3.500 or Auto Set
GROUND BOND (7440 ONLY)
Output Rating 30A/600m¥Ø, 8V
Output AC Current, A
3.00 - 30.00
0.01
¡¾ (2% of setting +3 counts)
Output AC Voltage, V
3.00 - 8.00
0.01
¡¾ (2% of setting +3 counts) at Open circuit
Output Frequency 50Hz/60Hz ¡¾100ppm, User Selection
SETTINGS
Hi-Limit Resistance, m¥Ø
0 - 150 (3 - 30A)
1
¡¾ (2% of setting +2 counts)
Lo-Limit Resistance, m¥Ø
0 - 600 (3 - 10A)
Lead Resistance Offset, m¥Ø
0 -200
1
¡¾ (2% of setting +2 counts)
Dwell Time, second 0, 0.5 - 999.9 sec (0=continuous) 0.1 ¡¾£¨0.1% + 0.05sec£©
MEASUREMENT
AC/DC Voltage, KV
0 - 6.00
0.01
¡¾£¨1.5% of reading + 1count£©
DC Voltage, V (IR)
100 - 1000
1
¡¾£¨1.5% of reading + 3V£©
AC Current Range, mA
0-3.500
0-3.500
0-3.500
0-3.500
0-3.500
3.00-30.00
3.00-20.00
3.00-30.00
3.00-40.00
3.00-40.00
AC Current Resolution, mA 0.001/0.01
AC Current Accuracy, mA ¡¾ (2% of reading + 3counts)
DC Current Range, µA
0-350.0
0.1
¡¾ (2% of reading + 3counts)
300 - 3500
1
3000-9999
10
AC Current, A (GB)
0 - 35.00
0.01
¡¾£¨2% of reading+3counts£©
Resistance, , M¥Ø(IR)
1 - 9999
(Auto Range)
0.001
0.01
0.1
1
¡¾£¨8% of reading+2counts£©at 100-500VDC,
1--1000 M¥Ø
¡¾£¨8% of reading+2counts£©at 500-1000VDC,
1000 -9999 M¥Ø
¡¾£¨8% of reading+2counts£©at 100-500VDC,
1 -1000 M¥Ø
Resistance, , m¥Ø (GB)
0 - 600
1
¡¾£¨2% of reading+2counts£©
GENERAL
Input Voltage AC 115/230Vac¡¾15%, 50/60Hz ¡¾ 5%, Fuse 5A Slow for 7410/7412 model, 6.3A Slow for 7420/7430/7440 model
PLC Remote Control Input : Test , Reset , Memory1.2.3
Output : Pass , Fail , Processing
Memory 50 memories, 8 steps/memory
Display 20¡¿2 LCD with back light
Key Lock To prevent unauthorized alteration of the test Parameters
Calibration Build-in software and external calibrated meters
Alarm Volume Setting Range: 0-9 ;0=OFF, 1 is softest volume, 9 is loudest volume.
Rear Panel Output
YES
YES
YES
YES
YES
Built-in Scanner
-
-
8channels
Option
Option
External Scanner
YES
YES
YES
YES
YES
Smart GFI
YES
YES
YES
YES
YES
Analog Meter
-
YES
-
YES
YES
RS232 Interface
Option
Option
Option
YES
YES
GPIB Interface
Option
Option
Option
Option
Option
Printer Interface
Option
Option
Option
Option
Option
TUV-GS listed
-
YES
-
YES
YES
CE Compliance
-
YES
-
YES
YES
Environment 0-40¡É, 20-80%RH
Dimension (W¡¿H¡¿D)
430¡¿133¡¿300 (mm)
430¡¿133¡¿500( mm)
430¡¿133¡¿500(mm)
Net Weight
12Kg
18Kg
22Kg
STANDARD ACCESSORIES
Power Cord(10A)
¡¿1
Fuses
¡¿2 (Including a spare contained in the fuse holder)
Hipot Test Lead ,1.5m(1101)
¡¿1
Return Test Cable(1102)
¡¿1 -
Hipot Return Lead ,1.8m(1103)
-
-
-
-
¡¿1
Ground Bond Return Lead 30A ,1.5m(1104)
-
-
-
-
¡¿1
Hipot Output Link Lead ,1.5m(1109)
-
-
¡¿8
-
-
RS232 Link Cable 1.5m(1130)
-
-
-
¡¿1
¡¿1
Disk ( RS232 test program )
-
-
-
¡¿1
¡¿1
*product specifications are subject to change without notice.
 
 
»ç¾÷ÀÚµî·Ï¹øÈ£ 113-01-57596| ¼­¿ï½Ã ±¸·Î±¸ ±¸·Îº»µ¿1258 Áß¾ÓÀ¯Åë´ÜÁö °¡µ¿ 2413È£ Åë½ÅÆǸŠÁ¦ 1918È£ | ´ëÇ¥ÀÚ¸í ±èâ¼ö
ÀÎâ°èÃø±â ÀüÈ­ 02-2616-4851 Æѽº 02-2616-4852
Copyright ÀÎâ°èÃø±â 2008 All rights reserved.