 mail:kcs465@naver.com   

 
 
:::ÇöÀçÀ§Ä¡ HOME ¢º Áß°íÁ¦Ç° ¢º Àü¿ø±â±â(AC/DC ÆÄ¿ö¼­ÇöóÀÌ/³»Àü¾Ð½ÃÇè±â/ÁÖÆļöº¯È¯±â/¼Ò½º¸ÞŸ) AC Voltage/Current Standa/½½¶óÀÌ´Ú½º ¢º ³»¾Ð Àý¿¬ ÃøÁ¤±â ¢º ³»Àü¾Ð½ÃÇè±â 19073 AC/DC/IR AC5KV ,DC6KV
    
Ãßõ»óÇ°
 
 
³»Àü¾Ð½ÃÇè±â 19073 AC/DC/IR AC5KV ,DC6KV
 
 

Product Overview    

 

AC/DC/IR HIPOT TESTER MODEL 19070 & 19050 SERIES 


Complete Dielectric Testing Solution The 19050 series electrical safety tester are advanced digital hipots with load and

line regulation to ensure the measurement integrity. Multi-step capability allows users to perform multiple tests in a 

sequence such as AC hipot followed by IR. The Chroma Hipot Tester 19050 series provide 3 models for choice. 

The 19052 for AC/DC/ IR Hipot testing and insulation resistance (IR) measurements.The model 19053 IR measurements 

with 8 scan channels;and the model 19054 IR measurements with 4 scan channels capability into a single compact unit. 

The Chroma Hipot Tester 19070 series provide 3 models for choice. The 19071 for AC Hipot testing, the 19073 which 

combines both AC and DC Hipot with insulation resistance (IR) measurements into a single compact unit.



Key Features


 AC/DC/IR 3 in 1 hipot tester

 AC 5kV and DC 6kV output

 1kV insulation resistance test

 Insulation resistance measurements from 1M¥Ø to 50G¥Ø

 Ground continuity check

 Open Short Check(OSC) function 

 GFI shutdown the instrument when

        imbalance current > 0.5mA

 Flashover(ARC) detection

 Quick discharge of DUT in IR and DC test

 Pause mode

 Large LCD display (240 x 64 dots matrix) 

 UL and TUV approved (*see spec)

 CE mark

 Programmable ramp/fall and test time

 Programmable high/low limit

 Save/Recall program test function

 Remote control and interface support 



Spec Comparison  


Model

19071

19073

19052

19053

19054

Mode

AC

AC/DC/IR

AC/DC/IR

AC/DCV/IR/SCAN

ACV/DCV/IR/SCAN

Scanner Unit

-

-

-

8 ports,¡¾phase

4 ports,¡¾phase

Withstanding Voltage Test

Output Voltage

AC : 0.05 5kV, DC 0.05 ~ 6kV

Load Regulation

1% of setting + 5V

Voltage Regulation

2V

Voltage Accuracy

1% of setting + 5 count

Cutoff Current

AC : 0.1~20mA,DC 0.01 ~ 5mA

AC : 0.1 30mA, DC 0.01 ~ 10mA

Current Resolution

AC : 1µA, DC : 0.1µA

Current Accuracy

1% of setting + 5 count

Output Frequency

50Hz / 60Hz

Test Time

0.3 999 sec., continue

Ramp Time

0.1 999 sec., off

Fall Time

0.1 999 sec., off

Dwell Time

0.1 999 sec., off

Waveform

Sine wave

Insulation Resistance Test

Output Voltage

-

DC 0.05 ~ 1kV

DC 0.05 ~ 1kV

DC 0.05 ~ 1kV

Voltage Resolution

-

2V

2V

2V

Voltage Accuracy

-

5% of setting

+ 5 count

1.5% of setting

+ 5 count

1.5% of setting + 5 count

IR Range

-

1M¥Ø~50G¥Ø

1M¥Ø~50G¥Ø

1M¥Ø~10G¥Ø

Resistance Resolution

-

0.1M¥Ø

0.1M¥Ø

0.1M¥Ø

Resistance  Accuracy

¡Ã 500V 

1M¥Ø~1G¥Ø

-

4% of setting

+ 5 count

5% of setting

+ 5 count

5% of setting + 5 count

1G¥Ø~10G¥Ø

-

7% of setting

+ 5 count

10% of setting

+ 5 count

10% of setting + 5 count

10G¥Ø~50G¥Ø 

-

12%5% of setting

+ 5 count

15% of setting

+ 5 count

15% of setting + 5 count

¡Â 500V 

1M¥Ø~1G¥Ø

-

7% of setting

+ 5 count

10% of setting

+ 5 count

10% of setting + 5 count

¡Â 100V 

1M¥Ø~1G¥Ø

-

10% of setting

+ 5count

Flashover (ARC) Detection

Setting Mode

Programmable setting

Detection Current

AC : 1mA 15mA, DC 1mA ~ 5mA 

AC : 1mA 15mA, DC 1mA ~ 10mA

Secure Protection Function

Fast Output Cut-off

0.4ms after NG happen

Ground Fault Interrupt

0.5mA ¡¾0.25mA AC, ON/OFF

Panel Operation Lock

Present password

Continuity Check

1¥Ø ¡¾ 0.2¥Ø, ON/OFF

GO/NG Judgment Window

Indication, Alarm

GO : Short sound, Green LED NG Long sound, Red LED

Data Hold

Least tests data memories

Memory Storage

50 instrument setups with up to 20 test steps

Remote & Interface

Remote control

Input : Start, Stop, Interlock (at 11 pin terminal block only) ; Output : Under test, Pass, Fail

Communication Interface

RS485 (Option)

RS232 (Standard), GPIB (Option).

General

Operation Environment

Temperature 0¡ÆC~40¡ÆC, Humidity 15% to 95% R.H@¡Â40¡ÆC

Power Requirements

100V/120V/220V/240V (AC ¡¾10%), 50/60Hz

Power Consumption

300W

500W

Dimension (W x H x D)

270 105 350 mm

320 105 400 mm

Weight

Approx.12 KG

Approx.15 KG

Certification

UL,TUV,CE

UL,TUV,CE

CE

UL,TUV,CE

 
 
»ç¾÷ÀÚµî·Ï¹øÈ£ 113-01-57596| ¼­¿ï½Ã ±¸·Î±¸ ±¸·Îº»µ¿1258 Áß¾ÓÀ¯Åë´ÜÁö °¡µ¿ 2413È£ Åë½ÅÆǸŠÁ¦ 1918È£ | ´ëÇ¥ÀÚ¸í ±èâ¼ö