½ÅÁ¦Ç°
Áß°íÁ¦Ç°
Àü±â¾ÈÀüÀåºñ
ESCOµî·ÏÀåºñ, ¿¡³ÊÁöÁø´ÜÀåºñ
½ÅÀç»ý¿¡³ÊÁö°ü·ÃÀåºñ
Á÷Á¢»ý»ê °Ë»ç¼³ºñ(¹ýÁ¤¼³ºñ)
write_poem
°øÁö»çÇ×
°í°´ °Ô½ÃÆÇ
Á÷°Å·¡ ÀåÅÍ
°í°´ ÀÚ·á½Ç
±¸¸Å|¸Å°¢ A/SÀÇ·Ú
 

  ¢Ï  °í°´¼¾ÅÍ

 TEL: 02-2616-4851

 FAX: 02-2616-4852

 H.P:010-3778-0143

 mail:kcs465@naver.com   

 
 
:::ÇöÀçÀ§Ä¡ HOME ¢º Áß°íÁ¦Ç° ¢º Àü¿ø±â±â(AC/DC ÆÄ¿ö¼­ÇöóÀÌ/³»Àü¾Ð½ÃÇè±â/ÁÖÆļöº¯È¯±â/¼Ò½º¸ÞŸ) AC Voltage/Current Standa/½½¶óÀÌ´Ú½º ¢º ³»¾Ð Àý¿¬ ÃøÁ¤±â ¢º 19032/Electrical Safety Analyzer
    
 
 
19032/Electrical Safety Analyzer
 
 

Key Features

  • Datasheet
  • AC/DC/IR/GB/LC/Dynamic Function – six instruments in one
  • Function test up to 20
  • Programmable voltage output and limit value
  • OSC open/short check
  • Flashover detection
  • Human protection circuit
  • Multi-scan device support dynamic leakage current test
  • Standard RS232 interface
  • Optional GPIB interface
  • Large LCD pane
  • Front panel lockout function
  • Support PC software
  • UL/TUV/CE
  • 2-Year factory warranty

Description

Electrical safety testing is a major item in electrical product quality testing. All electrical products like adapters, SMPS, charges, house appliances, information technology products, and video products are required to undergo electrical safety testing.

The 19032 series combines Hipot, Insulation Resistance (IR), Ground Bond (GB), Leakage Current (LC)/AC LC/DC LC and Dynamic Function Tests. Space savings can be up to 50% of production line space, through not purchasing multiple safety test instruments. The 19032 is able to increase the efficiency of electrical safety testing during manufacturing and reduce associated labor costs.

19032 Hipot Tester

Open/Short Check (OSC)

Patent No. 254135
All manufacturers have to solve the problems of error connections and unconnected test cables with their production line testers. Chroma¡¯s 19032 is equipped with an open/short check function (OSC) for product testing. This eliminates the potential for false failures.

 

Flashover Detection

The Guardian 19032 has the same Flashover Detection as many other Chroma safety test instruments. Flashover is electricity transient or non-sequential discharge on the inner surface of the insulation component which cause the DUTs original insulation to lose effectiveness, create a carbonized electrically conductive path to be generated, and damage the product. Flashover can¡¯t be detected by leakage current, test voltage or shift rate of leakage current is required. Thus, Flashover Detection is one of inevitable inspection item in HV test.

Safety Analyzer Leakage Current

 

Twinport¢â Function

Safety Analyzer Twinport
USA Patent No. IS6504381
The key factor affecting the efficiency of manufacturing is the efficiency for electrical safety test. The Twinport function reduces the safety test time and can eliminate potential bottlenecks in the production line.

 

Product Applications

The 19032 can be used in a variety of scenarios, which include quality assurance sample inspection testing, manufacturing testing, and development validation. Some example products are:

  • Power cords
  • House appliances
  • Information technology products
  • Medical equipment
  • Lab/testing equipment
  • EMI FILTERS

 

EN50191 Floating Output Function

The leakage current of any ground terminal should be lower than 3.5mA when operating Floating output function. This allows the operator near the ground terminal to avoid an electrical hazard.

 

Safety Test of Information Technology Product (IEC 60950)

Safety Analyzer TestInformation technology is a big part of our daily life. Desktops, notebooks, LCD monitors, UPS, printers, and projectors are products that we use in our everyday lives. To ensure proper safety, all products should have electrical safety tests performed. The 19032 offers all safety test functions and Normal/Reverse as well as Single Fault switch function (LC Test) to increase manufacturing efficiency.

Safety Analyzer AC ConnectionThe output floating of Telecommunication Network in IEC 60950 to perform dynamic leakage current test is required. The equivalent stray capacitance will also be generated on an isolation transformer, even if it is a floating circuit. The stray capacitance results in leakage current and electric shock to the users. The 19032, along with the 6000-05/07/08 leakage current scanner, have P1/P2 measurement functions which are able to measure dynamic leakage current on output terminals. It is the best solution for testing information technology products.

 


Main Test Item

  • Open Short Check
  • Ground Bond
  • AC/DC Hipot Test
  • Earth Leakage Current Test
  • Output Leakage Current Test

 

Power Supplies, Adapter & Charger Safety Testing

Safety Analyzer Power SupplyPower supplies in electronic products, including SMPS, adapters, and chargers, need to tested for electrical safety. According to various power design methods and test conditions, the 19032 offers programmable edit and solution, allowing the operator to complete all test at one time.

A number of power product designs must have the insulation capability of the input terminal (Primary) to output terminal (Secondary) that is sufficient to protect against damage inside the component. Thus, the output terminal or Floating needs to be Hipot tested. The 19032 provides an isolation test point with high voltage which allow you not to change the fixture or cable manually, and perform the P-S Hipot test directly after the P-G Hipot test.

If there is danger in making contact with the output terminal (Secondary), the dynamic leakage current test also needs to be performed.

Safety Analyzer Testing Chart

 

Safety Test of Video Product (IEC 60065)

Safety Analyzer Video TestVideo products include DVD recorders, LCD¡¯s, TV¡¯s, audio amplifiers, stereos and etc. These products have mass power output with separate safety standards. The main circuit design of mass power is a signal output terminal, not to mention an increase in temperature and heat dissipation of electronic component. Open voltage of some video products are over 35Vac peak or 60Vdc peak; this allows for U1 dynamic leakage current test as required. A U1 measurement circuit is added to the 19032 and P1/P2 measurement point is provided to comply with the requirement of safety standard test.

Main Test Item

  • Open Short Check
  • Ground Bond
  • AC/DC Hipot Test
  • Earth Leakage Current Test
  • Output LC Test

 

Safety Test of Home Appliance (IEC 60335)

Household appliances consist of ovens, refrigerators, televisions, juicers and coffee machines that may come in contact with a person. To ensure the safety of users, all products should preform electrical safety test. Except for the basic hipot test, dynamic leakage current has various test regulations by different ground modes and operation methods. The regulations are as listed in the table below.

Main Test Item

  • Open Short Check
  • Ground Bond
  • AC/DC Hipot Test
  • Earth Leakage Current Test

Safety Analyzer Appliance Test Chart

 

Safety Testing of Medical Equipment (IEC 60601)

Safety Analyzer Medical Equiptment Test19032 + 6000-07 is a solution for electrical safety and function test of medical equipment. The safety standard of medical equipment is very strict. Since the medical equipment comes in contact with the patient and hospital personnel, the instrument preforms various electrical safety test. The leakage current test has become one of the most important test in preforming electrical safety test.

The safety standard of medical equipment has various types of leakage current test. Also, normal/reverse/single fault normal/single fault reverse four powers and earth switch, make the safety test difficult and complex. The basic measuring circuit for the enclosure leakage current is as in the figure. It shows here measurement Type BF and CF is a special requirement for medical equipment. DC leakage current should be isolated separately and limited within 50uA limited, which is mentioned in the medical safety standard. This function has already been added to the 6000-08 LC scanner. The Chroma 19032 + 6000-07/08 offer programmable editing and software support. This allows you to test medical products without missing a procedure, as it saves the test data directly, providing the best test solution.

Main Test Item

  • Open Short Check
  • Ground Bond
  • AC/DC Hipot Test
  • Earth Leakage Current Test
  • Enclosure LC
  • Patient LC
  • Patient Auxiliary LC

 

Electric Vehicle Safety Test

The Automotive industry has switched focus from internal combustion engine power to electric power. Because the voltage of electric vehicles will be a maximum of up to 600V when in operation, it can be a safety issue. To avoid electrical injury, the Chroma 19032 is the best solution for electrical safety tests of wires and connectors for electrical vehicles, adapters, batteries and the charging system.

Main Test Item

  • Withstand voltage test: Various insulation terminals, primary and uncharged metal, withstand voltage between primary and secondary
  • Leakage current: All metallic parts can be touched on the system required to test earth leakage current during dynamic operation
  • Ground test: Ground protection connection should use 25A/60Hz current to test resistance; it cannot be higher than 100m§Ù

 

Measurement Technology

Open/Short Check (OSC) (Patent 254135)

OSC function is used to check the connection is open (bad contact) or short (DUT short) during the test procedure. When open occurred during test procedure, no good product will be judged as good product. When short occurred during test procedure, screening earlier to reduce the damage on equipment for saving test cost.

Generally speaking, the DUT has capacitive load (Cx) from tens to thousands pF under normal status. To form a micro capacitance on open circuit interface once connection is interrupted (as Cc in figure 2). Generally speaking, the capacitance is lower than 10pF thus total capacitance is far lower than the status of normal product. The capacitance is far higher than normal status when DUT short or close to short. Therefore, users judge the short problem by using high/low limit value of capacitance change.

Safety Analyzer Leakage Current

 

Capability of Controlling Chroma AC Source (6400/61600/61500 Series)

The manufacturers apply Chroma AC Source for power supply in order to promote input voltage stability ofdynamic leakage current test. The Guardian 19032 can use RS232 interface to control AC Source related models to let you more convenience in testing dynamic leakage current.

 

GFI Human Protection (Guardian 19032-P)

Safety Analyzer GFI Human ProtectionThe ultimate purpose of safety testing is protecting users from electric hazard. The Guardian 19032-P also has GFI function to protect operator. GFI function cut off the power output immediately while human body suffering electric shock. GFI function detects the current from Earth GND (Ioperator) and LOW terminal (Idevice). The voltage output will be cut off if the current is over 0.5mA.

 

Floating Circuit Function (Guardian 19032-P)

Safety Analyzer Floating Circuit FunctionChroma develops Floating circuit by all new technology in order to let operator to use safety test equipment safely. Whatever the operator touches any Hipot test terminal under Floating status. The earth leakage current is lower than 3.5mA, the operator won¡¯t be hurt by electricity.

 

Support Dynamic Leakage Current Test

The current brimmed after flow through insulation resistance, we called it as Leakage Current. When the leakage current contact with human body, the current flows to Earth via human body thus causes electric damage. The leakage current is testing under operating status. A human body RC network will be added in leakage current test, it can simulate the value of leakage current in real condition.

The leakage current has different test modes and standards in accordance with different safeties and test points. The most often seen current tests
are Earth Leakage Current, Patient Leakage Current and Patient Slave Leakage Current.

The Guardian 19032 is used with different dynamic leakage current module and human body simulation equivalent circuit for the requirements of various safety modules. It can apply to Electrical Safety Testing of House Appliance, Video Product, Medical Equipment and etc.

Safety Analyzer Dynamic Leakage Current Test

 

Mass Power Hipot Output Test (Guardian 19032-P)

The High Limit of Hipot test currently is often from 5 to 10mA. However, there is still a few of DUTs such as Safety Integrated Analyzer of EMI Filter or large-sized motor require mass power. The Guardian 19032-P promote the power of Guardian 19032 largely to let it equipped with the capabilities of outputting and measuring AC 100mA/DC 20mA.

Integrate Mass power Hipot test with other safety tests as a integrated analyzer for the users to use higher leakage current or large-sized electrical safety equipment. This brings the best efficiency to production line and quality assurance inspection.

The design of 500VA also comply with the requirement of IEC/UL output power to add the selection function of ¡°don¡¯t be protected by trip circuit under short current 200mA and 100mA¡±.

ModelDescription
Guardian 19032Electrical Safety Analyzer
Guardian 19032-PElectrical Safety Analyzer (500VA)
Accessories
A1903018HV Scanning Box
A1903025HV/3GC Scanner
A1903033HV/5GC Scanner
A1903048HV Scanner
A190305Line Leakage Current Scanner
A190306Hipot/Line Leakage/Probe Scanner (10A)
A190307L-N Scanner & Leakage Current Scanner
A190308Hipot/Line Leakage/Probe Scanner (20A)
9889¡°Soft Panel¡± software for Guardian 19032

User Manuals

Manuals - 19032 Electrical Safety Analyzer

One time registration required in order to download documents. Register or login to continue. 14.55 MB 85 downloads

User Manuals for 16502 Milliohm Meter. Available documents are: Quick Start Guide - 19032 Quick Start Guide - 19032P Hardware User Manual - 19032 Hardware User Manual - 19032P EST Softpanel User Manual All...

Specifications
Datasheet
Brochures

Electric Vehicle Testing Solutions

Download 2758.00 KB 1782 downloads

Brochure covering Chroma Electric Vehicle testing hardware. ...

Application Notes

Using an S14-09 Load Box to Verify the Performance of a Safety Analyzer

One time registration required in order to download documents. Register or login to continue. 531.31 KB 130 downloads

This application note discusses a method for confirming that earth leakage, enclosure leakage and /or patient leakage measurements within the safety analyzer are correct.  This method will determine whether...

Leakage Current Offset

One time registration required in order to download documents. Register or login to continue. 671 KB 126 downloads

This note describes how to use the Offset capability of the Chroma Guardian Electrical Safety Analyzer 19032-P for measuring leakage current of the DUT, not of the fixture, cables or the test instrument. ...

Connection Of Isolation Transformer To 19032

One time registration required in order to download documents. Register or login to continue. 555 KB 237 downloads

Describes the connection of an isolation transformer to an electrical safety test instrument. ...

What's Changing In Appliance Hipot Testing And Why

One time registration required in order to download documents. Register or login to continue. 515.00 KB 192 downloads

This application note provides information on changes in appliance hipot testing procedures. ...

Using Low Limits To Verify Hipot Connection

One time registration required in order to download documents. Register or login to continue. 535.00 KB 236 downloads

This application note illustrates how to use low limits to verify hipot connection to the device being tested. ...

UL Standard

One time registration required in order to download documents. Register or login to continue. 221 KB 238 downloads

This application note provides an overview of UL standards. ...

Using A Load Box To Verify A Tester Is Working

One time registration required in order to download documents. Register or login to continue. 623 KB 264 downloads

This application note demonstrates how to use a load box to verify that the hipot tester is functioning properly. ...

Testing Filter Capacitors On Medical Devices

One time registration required in order to download documents. Register or login to continue. 534 154 downloads

This application note will show how the hipot tester can be used not just as a means to check the DC Leakage Current or the Insulation Resistance, but can also be used to verify the existence and the value...

Tutorial On Safety Testing

One time registration required in order to download documents. Register or login to continue. 730 KB 285 downloads

This application note provides a tutorial on safety testing for UL certification of products. ...

Resistive Load Boxes For Hipot

One time registration required in order to download documents. Register or login to continue. 578 KB 236 downloads

This application note provides information on high voltage resistive load boxes and the manufacturers that make them. ...

Line Leakage Measurement & Human Body Equivalent Circuits

One time registration required in order to download documents. Register or login to continue. 246 KB 314 downloads

This note looks at the various line leakage tests and circuit models to determine possible patient/operator danger. ...

Leakage Current On Class I Medical Products

One time registration required in order to download documents. Register or login to continue. 379 KB 168 downloads

This application note describes how IEC 60601-1 leakage current tests can be accomplished without the need to change the cable to a class 1 device during testing. ...

Light Ballast Application

One time registration required in order to download documents. Register or login to continue. 640 KB 164 downloads

This note describes how to perform hipot tests on a light ballast. ...

Leakage Current On Class II Medical Products

One time registration required in order to download documents. Register or login to continue. 360 KB 204 downloads

This application note describes how IEC 60601-1 leakage current tests can be accomplished without the need to change the cable to a class 2 device during testing. ...

Leakage Current Part I

One time registration required in order to download documents. Register or login to continue. 271 KB 243 downloads

Part 1 discusses the terms and definitions associated with leakage current and the two classes that electronic medical products are divided into per IEC60601-1. ...

Leakage Current Part II

One time registration required in order to download documents. Register or login to continue. 291 KB 232 downloads

Part 2 builds on the basic principles of leakage current discussed in part 1 and details the IEC60601-1 measurement circuits for Earth, Touch/Chassis and Patient leakage current tests. ...

Hipot Testing Of Motors And Safety Standard Compliance

One time registration required in order to download documents. Register or login to continue. 261 KB 197 downloads

This application note describes the regulatory standards and tests that are applicable to hipot testing of motors. ...

Ground Bond, Ground Continuity And Earth Continuity

One time registration required in order to download documents. Register or login to continue. 456 KB 286 downloads

This application note covers the differences between Ground Bond, Ground Continuity And Earth Continuity tests, and how these tests can result in safer products. ...

Ensuring The Safety Of Medical Electronics

One time registration required in order to download documents. Register or login to continue. 279 KB 212 downloads

Vital areas of electrical safety testing for medical products include leakage current, dielectric breakdown, insulation resistance and ground bond testing. To better understand the differences in these...

Hipot Testing Multi Conductor Feedthroughs

One time registration required in order to download documents. Register or login to continue. 563 KB 231 downloads

This application note illustrates how to effectively perform electrical safety testing of IMD¡¯s with feedthroughs. ...

Dielectric Strength Testing Of External Cardiac Defibrillator

One time registration required in order to download documents. Register or login to continue. 758 KB 176 downloads

Explains testing procedures for cardiac defibrillators. ...

Testing to IEC60601 Standards

One time registration required in order to download documents. Register or login to continue. 1.16 MB 283 downloads

Testing to IEC60601 Standards: Leakage Current, Dielectric Breakdown, Insulation Resistance, and Ground Bond. There are a number of areas of safety testing, which include leakage current, dielectric breakdown,...

Electrical Safety Testing 101

One time registration required in order to download documents. Register or login to continue. 743 KB 561 downloads

This application note covers the basics of what electrical safety testing is, and the tests that can be performed. ...

Calculating Inrush Current Protection

One time registration required in order to download documents. Register or login to continue. 544 KB 208 downloads

This application note looks at protecting devices from high inrush currents and provides a method and considerations necessary in specifying the inrush current protection needed for an example device. ...

Custom Design Your Own Shock Therapy

One time registration required in order to download documents. Register or login to continue. 615 KB 171 downloads

This application note describes how to plan for product safety testing. ...

Advanced Technique For Dielectric Analysis

One time registration required in order to download documents. Register or login to continue. 221 197 downloads

This application note covers advanced techniques for dielectric analysis. ...

How To Buy

Three efficient ways to get pricing and/or more information regarding this instrument:

Electronically: Please complete this form and one of our sales engineers will respond same day or next business day if after hours. Requests from this form are quoted directly from Chroma.

By phone: Call us at 949-600-6400, let the operator know where you are located, and you¡¯ll be routed to your regional sales engineer.

By chat: Feel free to use the Chat line located at the bottom right of this page. The chat operator will take your information and route it to your regional sales engineer.

 

Want a quote for multiple instrument types? If you would like a quote for multiple instrument types, please use this form.

 

Lead time

Most of our instruments are inventoried and ready to ship. If we are currently out of stock – and due to demand we can be - lead times are typically 4-8 weeks depending on the instrument¡¯s power rating.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact Information

Required fields marked with *

Your Name *

Company *

Country *

Email *

Phone *

State or Province *

Requirements

Select required tests:
 AC Hipot AC/DC Hipot Ground Bond (GB) Leakage Current (LC) Insulation Resistance (IR) Corona Discharge (CD) Impulse Winding Test (IWT)

Additional Requirements or Comments:

Check below

 

Related Products

 
 
»ç¾÷ÀÚµî·Ï¹øÈ£ 113-01-57596| ¼­¿ï½Ã ±¸·Î±¸ ±¸·Îº»µ¿1258 Áß¾ÓÀ¯Åë´ÜÁö °¡µ¿ 2413È£ Åë½ÅÆǸŠÁ¦ 1918È£ | ´ëÇ¥ÀÚ¸í ±èâ¼ö
ÀÎâ°èÃø±â ÀüÈ­ 02-2616-4851 Æѽº 02-2616-4852
Copyright ÀÎâ°èÃø±â 2008 All rights reserved.