:::ÇöÀçÀ§Ä¡ HOME ¢º Áß°íÁ¦Ç° ¢º Àü¿ø±â±â(AC/DC ÆÄ¿ö¼­ÇöóÀÌ/³»Àü¾Ð½ÃÇè±â/ÁÖÆļöº¯È¯±â/¼Ò½º¸ÞŸ) AC Voltage/Current Standa/½½¶óÀÌ´Ú½º ¢º ³»¾Ð Àý¿¬ ÃøÁ¤±â ¢º Chroma 19570 Ground Bond Tester
    
 
 
Chroma 19570 Ground Bond Tester
 
 
Ground Bond Tester
Model 19570
Ground Bond Tester
Ground Bond Tester
Model 19570


Applications

  • Verifying integrity of ground connection on appliances and instruments which use 3 prong power cord
  • Tests for chassis to ground resistance
  • Electric motor safety test
  • Variety of medical applications
  • Extensive coverage for the testing of UL, CSA, VDE, IEC and other agency safety requirements

19570 Data Sheet
Click to view in PDF format  (180 KB)

      

  • TUV approved
  • CE certified
  • High current ground continuity testing up to 30Amps
  • Resistance measurements from 0.1m¥Ø up to 510m¥Ø
  • Large LCD display (240 x 64dot matrix) can supply great view of test result and setting functions
  • 4 terminal kelvin connections make higher accuracy
  • Programmable high and low resistance limits
  • Adjustable test time from 0.1 to 999 seconds
  • Built-in calibration via software
  • Automatic offset of lead resistance
  • Built-in resistance compensation function
  • Compatible with the 19070 series Hipot Tester
  • Digital readout of current,resistance and test time
  • Front panel lockout
  • Remote control
  • Storage of 10 tests setups
  • Beeper on/off
  • Easy to use
 

The Ground Bond Tester 19570 provides high current testing of ground continuity between chassis and power cord ground on a wide variety of electrical products and appliances. The unit is designed for maximum flexibility and operation convenience in mind.

The simple front panel of the tester requires less effort to operate. The Digital display and user friendly control allow test parameters and limits to be set easily without activating the high voltage. The instrument can be put on line rapidly. It can provide operators useful measurements with little to no training.

The use of a high current AC test provides a better simulation of how the ground on the device would perform under actual conditions if the motor or wiring was to short to ground. This verifies that the grounds in the device can handle 25 or 30 Amps until a circuit breaker trips or fuse blows. Most European standards such as TUV, IEC, VDE, BABT and CSA recommend this type of testing. In contrast, the ground continuity test that is provided as part of most hipot testers just checks to make sure there is a connection.

High and Low Resistance Limits
The 19570 offers a resistance measurement range from 0 to 510m¥Ø. The high and low resistance limits with pass/fail indication are also user programmable.

Remote Control
The 19570 can be incorporated into an automated manufacturing environment with remote start and GO/NOGO results output through the rear panel PLC interface.

The 19070 Series Hipot Tester Compatibility
The 19570 can be used alone or connected to Chroma 19071/19072/19073 for complete product test with the push of one button. When the 19570 has completed a continuity test, with pass indicated, it can remotely start the 19071/19072/19073 for a hipot test in sequence.

Built-In Calibration Via Software
The front panel display of an operation promoted calibration routine requires no internal adjustments.

 

Specifications
Model 19570
Mode Ground Bond
Withstanding Voltage Test
Output Voltage AC : 1~ 30 A, 0.01A step
Load Regulation 1 % + 0.3 A
Resolution 10mA
Current Accuracy 1 % + 0.3 A
Output Frequency 50 Hz / 60 Hz
Resistance Range 0 ~ 510 m¥Ø
Resistance Resolution 0.2 m¥Ø
Resistance Accuracy 1 % + 5 counts
Offset
  • A predetermined value can be subtracted from the measured value and the result of subtraction can be display
  • The result of subtraction can be compared with a Good/NO Good judgment reference value, and the result of comparison can be use for the Good/NO Good judgment
Offset Range 0 ~ 100 m¥Ø
Test Time 0.3 sec. ~ 999.9 sec., continue
Waveform Sine wave
GO/NG Judgment
  • A no-good judgment is made when a resistance greater than the high limit value is detected.
  • A no-good judgment is made when the output current is cutout and a no-good alarm signal is delivered.
  • If no abnormal state is detected during the test time, a good judgment is made and a good signal is deliver.
Limit HI-Limit 0 ~ 510 m¥Ø
General
Operation Environment Temperature 0 ~ 40 ¡ÆC
Humidity ¡Â 80 % RH
Power Consumption no-load (Ready state): < 100 W
with Rated Load : 500 W max
Power Requirement 100 V / 120 V / 220 V AC ¡¾10%, 240V AC+5%~-10%
50 / 60 Hz
Weight 9.5 kg approx.
Dimension(W x H x D) 320 x 105 x 400 mm

 

Order Information
19570 Ground Bond Tester
A190701 Remote Control Box
A195701 RS-232 Interface
 
 