Telephone Acoustic Analyzer, Type 1700Àº Àüȱ⠰³¹ß, »ý»ê, Ç°Áú°ü¸® µî¿¡¼ ÁÖ·Î »ç¿ëÇϸç, ¼Û¼öÈ ¹× ÃøÀ½´ç·®/ Return Loss/ Distortion/ Impedance/ H.A.C. µîÀ» ÃøÁ¤ÇÕ´Ï´Ù. OptionÀÇ Ãß°¡·Î EIA, CCITT, OREMA/Bµî ¾à 30¿© ±¹°¡ÀÇ ±Ô°ÝÀ» ¸¸Á·ÇÕ´Ï´Ù.
Specifications
¡à Feeding Bridge Voltage£º
Symmetric Balanced Type. Voltage can be set from 5¢¦73V ¡¾( 0.4﹪rdg £« 0.15﹪FS )
resolution: 0.1V, program-mable Software Setting.
Current : 0¢¦120 ma. Accuracy£º
0¢¦2 ma¡¾(2.5﹪£« 2ua)£»Resolution 1ua; 2¢¦120 ma ¡¾ ( 1.5﹪£«0.1 ma ).
Resistance£ºRtot£½RL1£«RL2£«Rv ;
RL1£½RL2£½150¥Ø£½Resistance of the Inductor; Rv£½ Resistance of the programmable Ser-ial Resistor ; Rv = 0¢¦2550¥Ø (overall from 300¥Ø¢¦ 2850¥Ø, 10¥Ø / Step).
Coupling capacitor£º2u¡¿2, 4u¡¿2, 37u¡¿2, programmable and set automatically according to specific standard. (see Note 3).
¡à Sweep frequency range£º
In the range between 100 Hz¢¦10 KHz. The working range is determined according to specific standard automatically, e.g.:180Hz~5KHz according to Taiwan, EIA or China Std., or 160 Hz¢¦8 KHz according to BS6317 .
¡à Resolution or interval of sweep frequencies£º( user selectable )
Fast : 1/12 oct.
Slow£º1/48 oct. ( ¡Ö continuous ) .
¡à Test standard£ºITU-T (CCITT)¡¢EIA (IEEE)¡¢OREM A¡¢OREM B
¡à Frequency response judgement : Mask ( Best Fit ) or 1KHz Normalization method. Automatically set According to specific standard.
¡à Dynamic range of freq. response meas. : 70 dB.
¡à Sending test range£º£«10 ¢¦ £60 dBV
¡à Receiving test range£º50 ¢¦ 120 dB SPL
¡à Sidetone test range£º50 ¢¦ 120 dB SPL
¡à Sound level from Artificial Mouth : 75¢¦107dBSPL@MRP. Set by the software in step 0.1dB.
¡à Artificial Line : 0¢¦ 7.5 Km, 0.5 Km / Step ; or 0¢¦ 15 Kft , 1 Kft / Step ( EIA ).
¡à Electrical signal for receiving test£º
EMF =0.07V ¢¦3V, set by the software in step 0.1dB, accuracy £¼¡¾ (0.1 dB£«1mv).
¡à Test range of RE or LR£º
EIA |
CCITT |
OREM A / B |
TOLR£º £20 ¢¦ £ 65 dB |
SLR£º £15¢¦£« 30 dB |
TRE£º£20 ¢¦£« 25 dB |
ROLR£º £«30¢¦£«75 dB |
RLR£º £20¢¦£« 25 dB |
RRE£º£15 ¢¦£« 30 dB |
SOLR£º £20 ¢¦£«25 dB |
STMR£º£10¢¦£« 35 dB |
SRE£º£25 ¢¦£« 20 dB |
¡à Tighten or Loosen of Upper / Lower limits range£º£9.9¢¦£« 9.9 dB, 0.1dB/step.
¡à Return Loss Measurement£º
Terminal Impedance£ºInternal : 600¥Ø, 900¥Ø and 3 different complex impedance according to UK, China and Germany standards.
External : Three additional Zext terminals are provided.Test range: 0¢¦40 dB ( Note£º£¾ 40 dB is meaningless ),
Accuracy :
300Hz¢¦4KHz ¡¾ 0.3dB @ 0¢¦ 30 dB
¡¾ 0.6dB @ 30¢¦ 35 dB
¡¾ 1dB @ 35¢¦ 40 dB
Frequency range£ºDetermined by specific std. ranging from 100 Hz¢¦ 10 KHz .
¡à Printer interface : HP or compatible.
¡à Power£º90V¢¦240V, 47¢¦63Hz, 150VA max..
¡à Weight & dimension£º N.W.£º( H )¡¿( W )¡¿( D )
MODEL£170 : 9.5 Kgs. 17 ¡¿ 36 ¡¿ 39 CM
14" MONITOR : 11.5 Kgs. 37 ¡¿ 35 ¡¿ 39 CM
MODEL£147 : 6.5 Kgs. 49 ¡¿ 21 ¡¿ 30 CM ( Test Head ) |