166/Pulse Function Generator
 
 
Pulse Function Generator

-0.0001 Hz to 50 MHz Range
-30 Volt Peak-To-Peak Output
-Lin/Log Sweep Plus AM and FM
-Pulse Width and Transition Time Control
-Independent Pulse Width and Rate
-SWEEP/FUNCTION GENERATOR

*Selectable Waveforms : Sine,triangle,  square and ramp.AII can be inverted.
  AII can be amplitude and frequency modulated
 *Operational Modes : Continuous,Triggered, Double Triggered,Triggered Haverwave,Gated,
   Gated Haverwave,Continuous Sweep,Triggered  Sweep and Sweep and Hold
 *Frequency Range : 0.0001 Hz to 50 MHz in 11 ranges.Maximum sweep 1000:1 in lin or log
 *Sweep Time Range : 100s to 100§Á in 6 ranges
 *Function Output : Variable to 30 Vp-p(15 Vp-p into 50 §Ù).Voltage attenuation 0 to 80 dB:
  to 60 dB in 20 dB steps,plus 20 dB steps, plus 20 dB continuous vernier
 *DC Offset : DC offset of all waveforma is adjustable to ¡¾ 10V(¡¾  5V into 
                       50§Ù).Waveform plus offset is limited to  ¡¾  15V( ¡¾7.5V into 50 §Ù)
 *GCV Output : 0 to +5V(nominal,open circuit)

-AMPLITUDE PRECISION
 *Amplitude Change With Frequency : 
     Sine and square variations :
     <¡¾0.1 dB to 100 KHz;
     <¡¾0.2 dB to 1 MHz;
     <¡¾3 dB to 50 MHz.
 *Step Attenuator Accuracy : ¡¾0.3 dB to 20 dB  step to 100 KHz

-PULSE GENERATOR
 *Pulses : Varable amplitude positive or  comple-mentary pulses  
*Operational Modes : Continuous,Triggered, Double Triggered,Gated and Continuous 
                                     Sweep.
  External Width : The trigger input 
  determines the output pulse width and  period
 *Pulse Period Range : Pulse period is   selectable from 20 ns to 10,000s(50 MHz to 
                                     0.0001 Hz)with approximately 1 % vernier
 *Pulse Width : 10 ns 100 msin 7 ranges.
  Maximum duty cycle is 70 % for periods to 200 ns,decreas-ing to 50 % for 20 ns periods.
  Control has nominal 5 % duty cycle detent
 *Transition Time : 7 ns to 50 ms in 7 ranges,  independently variable for leading and
                                 trailing edges.
 *Function Output : 0 to ¡¾15V into open circuit  (0 to ¡¾7.5V into 50 §Ù).Voltage attenuation 
                                 0 to 80 dB
 *TTL and TTL Pulses : Transition times less  than 4 ns into 50 §Ùtermination
 
 