½ÅÈ£¹ß»ý±â(Æò¼ÇÁ¦³Ê·¹ÀÌÅÍ/½Ã±×³¯Á¦³Ê·¹ÀÌÅÍ/¿À½Ç·¹ÀÌÅÍ)
¢º
Pulse-Sweep Function Generator
¢º 166/Pulse Function Generator
166/Pulse Function Generator
Pulse Function Generator
-0.0001 Hz to 50 MHz Range
-30 Volt Peak-To-Peak Output
-Lin/Log Sweep Plus AM and FM
-Pulse Width and Transition Time Control
-Independent Pulse Width and Rate
-SWEEP/FUNCTION GENERATOR
*Selectable Waveforms : Sine,triangle, square and ramp.AII can be inverted.
AII can be amplitude and frequency modulated
*Operational Modes : Continuous,Triggered, Double Triggered,Triggered Haverwave,Gated,
Gated Haverwave,Continuous Sweep,Triggered Sweep and Sweep and Hold
*Frequency Range : 0.0001 Hz to 50 MHz in 11 ranges.Maximum sweep 1000:1 in lin or log
*Sweep Time Range : 100s to 100§Á in 6 ranges
*Function Output : Variable to 30 Vp-p(15 Vp-p into 50 §Ù).Voltage attenuation 0 to 80 dB:
to 60 dB in 20 dB steps,plus 20 dB steps, plus 20 dB continuous vernier
*DC Offset : DC offset of all waveforma is adjustable to ¡¾ 10V(¡¾ 5V into
50§Ù).Waveform plus offset is limited to ¡¾ 15V( ¡¾7.5V into 50 §Ù)
*GCV Output : 0 to +5V(nominal,open circuit)
-AMPLITUDE PRECISION
*Amplitude Change With Frequency :
Sine and square variations :
<¡¾0.1 dB to 100 KHz;
<¡¾0.2 dB to 1 MHz;
<¡¾3 dB to 50 MHz.
*Step Attenuator Accuracy : ¡¾0.3 dB to 20 dB step to 100 KHz
-PULSE GENERATOR
*Pulses : Varable amplitude positive or comple-mentary pulses
*Operational Modes : Continuous,Triggered, Double Triggered,Gated and Continuous
Sweep.
External Width : The trigger input
determines the output pulse width and period
*Pulse Period Range : Pulse period is selectable from 20 ns to 10,000s(50 MHz to
0.0001 Hz)with approximately 1 % vernier
*Pulse Width : 10 ns 100 msin 7 ranges.
Maximum duty cycle is 70 % for periods to 200 ns,decreas-ing to 50 % for 20 ns periods.
Control has nominal 5 % duty cycle detent
*Transition Time : 7 ns to 50 ms in 7 ranges, independently variable for leading and
trailing edges.
*Function Output : 0 to ¡¾15V into open circuit (0 to ¡¾7.5V into 50 §Ù).Voltage attenuation
0 to 80 dB
*TTL and TTL Pulses : Transition times less than 4 ns into 50 §Ùtermination