Keysight Technologies E4980AL Precision LCR Meter 20 Hz to 300 kHz/500 kHz/1 MHz Providing the best combination of accuracy, speed and versatility 02 | Keysight | E4980AL Precision LCR Meter - Brochure Keysight¡¯s E4980AL precision LCR meter provides the best combination of accuracy, speed, and versatility for a wide range of component measurements. Offering fast measurement speed and outstanding performance at both low and high impedance ranges, the E4980AL is the basic tool for general R&D and manufacturing test of components and materials. Fast measurement speed The E4980AL offers excellent speed: –– 12 ms (SHORT)1 –– 118 ms (MED)1 –– 343 ms (LONG)1 Accurate measurements Exceptionally low noise at both low and high impedance for evaluating the characteristics of inductors and capacitors with excellent accuracy and repeatability. –– 0.05% basic impedance accuracy –– 1/2/4m cable extension capability –– Open/Short/Load correction DC bias Built-in DC-voltage-bias source provides accurate bias dependency evaluation for C, L, and material measurements. –– 1.5 V and 2 V 1. Measurement time at 1 MHz. Supplemental information. For additional details, refer to the E4980A/E4980AL data sheet (literature number 5989-4435EN). High-resolution LCD display Full, 7-digit display and 6 display modes for clear and easy viewing. LED status lights Conveniently view DC bias and USB memory status. Simple and intuitive operation Easily configure measurements with soft keys (same interface as Keysight¡¯s 4284A LCR meter), one-touch front panel keys and an intuitive user interface. USB interface (memory devices only) Easily save measurement states, data logs, and screen captures to USB memory devices. 100 ¥ìV to 2 Vrms variable test signals Provides signal levels to evaluate the AC voltage characteristics of your devices. A Standard LCR Meter 03 | Keysight | E4980AL Precision LCR Meter - Brochure 1. Measurement time at 1 MHz. Supplemental information. For additional details, refer to the E4980A/E4980AL data sheet (literature number 5989-4435EN). Compact and light weight Small size for easy transportation –– 370 (W) x 105 (H) x 390 (D) mm –– 5.3 kg (11.7 lb.) Standard LAN/USB/GPIB interface Flexible PC connectivity and fast transfer speed –– 10/100 Base-T LAN –– USB (USBTMC) interface –– GPIB for robust instrument control and test automation External trigger Key Features Accurate measurements Exceptionally low noise at both low and high impedance to improve test quality. –– 0.05 % basic impedance accuracy –– Open/Short/Load compensation support –– Cable extension (1/2/4m) support Fast measurement speed1 Fast speed provides more throughput reducing cost of test. –– 12 ms (SHORT) –– 118 ms (MED) –– 343 ms (LONG) Measurement versatility –– 20 Hz to 300 kHz/500 kHz/1 MHz test frequency with 4-digit resolution at any frequency –– 16 impedance parameters –– 100 ¥ìV to 2 Vrms, 1 ¥ìA to 20 mA variable test signal –– Auto-level control –– 201 points of programmable list sweep –– DC resistance Optional handler and scanner interfaces Two interface options to choose from: – Handler interface with 9 BIN outputs (Option E4980AL-201) – Scanner interface with 128 multi-channel corr ection (Option E4980AL-301) 04 | Keysight | E4980AL Precision LCR Meter - Brochure Broad range impedance measurements The E4980AL LCR meter offers excellent performance for all impedance measurements. Reliable measurement performance is needed to meet the test requirements of today¡¯s latest devices. The E4980AL offers fast measurement speed and outstanding performance within ¡°both¡± low and high impedance ranges with exceptional dissipation factor accuracy. Stable small ESR/low impedance measurements The equivalent series resistance (ESR) of capacitors is becoming smaller and smaller to meet high-speed and low power-consumption circuit needs; and is difficult to measure. The E4980AL provides exceptional measurement stability. Exceptionally accurate, high impedance measurements The capacitance values of chip-capacitors are now down to femto-farad (fF) range. Thus, very stable and accurate high impedance measurements are required for higher yields and design reliability. Surpassing Agilent¡¯s previous industry-standard LCR meter (4284A), the E4980AL further improves measurement stability for these small capacitance devices. 1. Measurement time at 1 MHz. Supplemental information. For additional details, refer to the E4980A/E4980AL data sheet (literature number 5989-4435EN). 2. Applied up to 300 kHz/500 kHz/1 MHz for E4980AL. Accurate, Fast Measurements up to 300 kHz/500 kHz/1 MHz Accurate measurements provide design and test confidence Figure 1. 10% impedance measurement accuracy range. Test signal 1 Vrms, MED mode, cable 0m2 Offering the industry¡¯s best combination of speed and accuracy Fast measurement speed for more throughput in manufacturing –– 12 ms per point at 1 MHz with SHORT mode1 –– 118 ms per point at 1 MHz with MED mode1 –– 343 ms per point at 1 MHz with LONG mode1 Average function (up to 256) Enables users to improve measurement repeatability. 05 | Keysight | E4980AL Precision LCR Meter - Brochure Versatile Measurement Capability to Meet your Application Needs Powerful features increase test reliability and efficiency Figure 2. Select one of six display modes Figure 3. List sweep mode Figure 4. DCR measurement Six convenient display modes Select one of six display modes to suit your particular measurement needs. –– Normal view for a data overview –– Large display view for enhanced readability –– BIN No. view for measurement comparison and device sorting –– BIN count view for statistical evaluation –– LIST sweep view for continuous data –– Blank page view for ultimate speed (Turns off display to save refresh time.) 201 points list sweep Frequency, measurement range, and stimulus conditions, can be set as list parameters (max 201 points). You can choose two parameters independently to test under a variety of measurement conditions. DC resistance measurement For inductor measurements, Ls or Lp and Rdc parameters can be measured at the same time. 06 | Keysight | E4980AL Precision LCR Meter - Brochure Support for a wide variety of test fixtures The E4980AL can be used with over twenty fixtures to meet a variety of evaluation needs; from materials to SMD components. Also, built-in compensation functions minimize the influence of test fixtures. USB memory support The front panel USB memory interface allows you to quickly and easily save state files, measurement log data, and display images to an external USB memory device (mass storage). PC connectivity Standard GPIB/LAN/USB control interfaces provide a variety of paths for controlling the instrument. Using a LAN cable, you can even control the E4980AL with a computer and Web browser. Scanner or handler interface options The E4980AL offers an optically-isolated 9-BIN handler (Option 201) for integration into handler systems. A 128-channel scanner interface (Option 301) facilitates applications requiring a component scanner. Both interfaces have standard compatibility with other LCR system instruments (e.g. 4284A/88A/78A, etc.) for easy integration into systems. The multi-compensation function enables open/short/load compensations to perform scanning measurements independently in each scanner channel. This minimizes inconsistency in measured values between channels for more accurate measurements throughout the scanner system. Upgradability Following upgrade options are available. –– E4980ALU-050 or 052: 300 kHz to 500 kHz –– E4980ALU-110 or 112: 300 kHz to 1 MHz –– E4980ALU-111 or 113: 500 kHz to 1 MHz –– E4980ALU-201 or 211: Add handler interface –– E4980ALU-301 or 311: Add scanner interface Refer to the configuration guide for more details. Figure 5. The E4980AL LCR meter offers support for a wide variety of test fixtures Figure 7. The E4980AL LCR meter can conveniently be controlled over LAN with a computer and a Web browser Figure 6. Example of use with USB storage device Exceeding Expectations in Productivity 07 | Keysight | E4980AL Precision LCR Meter - Brochure Quick Product Comparison 4263B LCR meter (Discontinued) E4980AL Precision LCR meter E4980A Precision LCR meter Frequency 100, 120, 1 k, 10 k, 20 k, and 100 kHz 20 Hz to 300 k/500 k/1 MHz 20 Hz to 2 MHz Test signal level 20 m to 1 Vrms 0 to 2 Vrms/0 to 20 mArms 0 to 2 Vrms or 20 Vrms (Option 001) /0 to 20 mArms or 100 mArms (Option 001) Auto level control (ALC) No Yes Yes DC bias capability 1.5 V, 2 V Built-in 1.5 V, 2 V 1.5 V, 2 V or ¡¾ 40 V (Opt. 001) Programmable list sweep No 201 points 201 points Remote control GPIB GPIB, LAN, USB GPIB, LAN, USB Web browser control No Yes Yes Interface option Handler Handler (Option 201) / Scanner (Option 301) Handler (Option 201) / Scanner (Option 301) Parameters Impedance, DCR, N, M Impedance, DCR Impedance, DCR (Option 200) Control commands 4263B unique E4980A/4284A compatible E4980A/4284A compatible Basic accuracy 0.1% @ Medium 0.1% @ Short 0.05% @ MED/LONG 0.1% @ Short 0.05% @ MED/LONG Measurement time mode 25 ms Short mode, 65 ms Medium mode 149 ms @ 100 Hz 26 ms @ 1 kHz 12 ms @ 1MHz Short mode 100 ms @ 100 Hz 20 ms @ 1 kHz 5.6 ms @1 MHz Short mode Storage devices Internal Internal/USB memory Internal/USB memory Cable length 0, 1, 2, 4 m 0, 1, 2, 4 m 0, 1, 2, 4 m Cabinet dimensions (mm) 320 (W) x 100 (H) x 300 (D) 370 (W) x 105 (H) x 390 (D) 370 (W) x 105 (H) x 390 (D) Weight 4.5 kg 5.3 kg 5.3 kg 08 | Keysight | E4980AL Precision LCR Meter - Brochure Ordering Information E4980AL Precision LCR Meter, 20 Hz to 300 kHz/500 kHz/1 MHz Options Model Description E4980AL-032 20 Hz to 300 kHz with DCR Measurement E4980AL-052 20 Hz to 500 kHz with DCR Measurement E4980AL-102 20 Hz to 1 MHz with DCR Measurement E4980AL-201 Handler interface E4980AL-301 Scanner interface E4980AL-1CM Rack mount kit E4980AL-ABA English localization E4980AL-ABJ Japanese localization E4980AL-1A7 ISO 17025 compliant calibration E4980AL-A6J ANSI Z540 compliant calibration For more details on the option configuration, refer to the E4980A/E4980AL configuration guide (literature number 5989-8321EN). Upgrade options Model Description E4980ALU-050 or 052 Upgrade from 300 kHz to 500 kHz for E4980AL-032 E4980ALU-110 or 112 Upgrade from 300 kHz to 1 MHz for E4980AL-032 E4980ALU-111 or 113 Upgrade from 500 kHz to 1 MHz for E4980AL-052 E4980ALU-201 or 211 Handler interface E4980ALU-301 or 311 Scanner interface 1CM019A Rack mount kit Refer to the configuration guide for more details. Web Resources Visit our E4980AL Web site for additional product information and literature. www.keysight.com/find/E4980AL LCR Meters & Impedance Measurement Products www.keysight.com/find/impedance 09 | Keysight | E4980AL Precision LCR Meter - Brochure This information is subject to change without notice. © Keysight Technologies, 2013 - 2014, 2017 Published in USA, August 18, 2017 5991-2305EN www.keysight.com For more information on Keysight Technologies¡¯ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-6-20-17) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System www.keysight.com/find/e4980al Evolving Since 1939 Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight. myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Keysight Services www.keysight.com/find/service Keysight Services can help from acquisition to renewal across your instrument¡¯s lifecycle. Our comprehensive service offerings—one-stop calibration, repair, asset management, technology refresh, consulting, training and more—helps you improve product quality and lower costs. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight¡¯s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. And, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight¡¯s measurement expertise and product breadth, combined with channel partner convenience.![1715954638792.png](/inchangtestcokr/down/item/1715954638792.png) |