½ÅÁ¦Ç°
Áß°íÁ¦Ç°
Àü±â¾ÈÀüÀåºñ
ESCOµî·ÏÀåºñ, ¿¡³ÊÁöÁø´ÜÀåºñ
½ÅÀç»ý¿¡³ÊÁö°ü·ÃÀåºñ
Á÷Á¢»ý»ê °Ë»ç¼³ºñ(¹ýÁ¤¼³ºñ)
write_poem
°øÁö»çÇ×
°í°´ °Ô½ÃÆÇ
Á÷°Å·¡ ÀåÅÍ
°í°´ ÀÚ·á½Ç
±¸¸Å|¸Å°¢ A/SÀÇ·Ú
 

  ¢Ï  °í°´¼¾ÅÍ

 TEL: 02-2616-4851

 FAX: 02-2616-4852

 H.P:010-3778-0143

 mail:kcs465@naver.com   

 
 
:::ÇöÀçÀ§Ä¡ HOME ¢º Áß°íÁ¦Ç° ¢º È¸·Î¼ÒÀÚÃøÁ¤±â(LCR¹ÌÅÍ/ÀÓÇÇ´ø½º¹ÌÅÍ/¸Þ°¡¿È¸ÞŸ/ÀúÇ×¹Ú½º/)Curve Tracer ¢º LCR-LCZ Meter ¢º 4268A 120Hz/1kHz ijÆнÃÅϽº ¹ÌÅÍ
    
Ãßõ»óÇ°
 
 
4268A 120Hz/1kHz ijÆнÃÅϽº ¹ÌÅÍ
 
 

ÃøÁ¤ ½Ã°£

  • °í¼Ó ÃøÁ¤: 25ms

Ãß°¡ Ư¡

  • ³ôÀº °ªÀÇ ¼¼¶ó¹Í ijÆнÃÅÍ Å×½ºÆ®¸¦ À§ÇÑ ÀÏÁ¤ÇÑ Å×½ºÆ® ·¹º§
  • ºü¸¥ Á¢ÃË È®ÀÎ
  • 9-bin ºñ±³±â

Å°»çÀÌÆ® 4268A ijÆнÃÅϽº ¹ÌÅ͸¦ ÅëÇØ ÀÏÁ¤ÇÑ ³ôÀº Å×½ºÆ® ½ÅÈ£ ·¹º§°ú ³ôÀº ¼Óµµ¿¡¼­ °í¿ë·® ´ÙÃþ ¼¼¶ó¹Í ijÆнÃÅÍ(MLCC)¸¦ Å×½ºÆ®ÇÒ ¼ö ÀÖ½À´Ï´Ù. ÀÏÁ¤ Å×½ºÆ® ·¹º§ ±â´ÉÀº 1kHz, 1Vrms¿¡¼­ ÃÖ´ë 70uF¿¡ ´ëÇØ IEC 384-10 Ç¥ÁØÀ» ÁؼöÇÏ¿© MLCC¸¦ Å×½ºÆ®ÇÒ ¼ö ÀÖµµ·Ï ÇÕ´Ï´Ù. 120Hz ÃøÁ¤Àº ÃÖ´ë 600uF¿¡ ´ëÇØ ÀÏÁ¤ÇÑ 1rms Å×½ºÆ® ½ÅÈ£¸¦ º¸ÀåÇÕ´Ï´Ù. Å°»çÀÌÆ® 4268A´Â 25ms ³»¿¡¼­ ºñ±³ ÃøÁ¤±â °á°ú¿Í ÇÔ²² ÃøÁ¤ °ªÀ» Á¦°øÇϱ⠶§¹®¿¡ MLCC »ý»ê ¶óÀο¡¼­ Å×½ºÆ® 󸮷®À» ±Ø´ëÈ­ÇÒ ¼ö ÀÖ½À´Ï´Ù.


1. Basic Specifications Measurement parameters • Cp-D, Cp-Q, Cp-Rp, Cp-G • Cs-D, Cs-Q, Cs-Rs Where: Cp: Measured capacitance value using the parallel equivalent circuit model Cs: Measured capacitance value using the series equivalent circuit model D: Dissipation factor Q: Quality factor (inverse of D) G: Measured equivalent parallel conductance using the parallel equivalent circuit model Rp: Measured equivalent parallel resistance using the parallel equivalent circuit model Rs: Measured equivalent series resistance using the series equivalent circuit model Measurement conditions • Measurement signal Frequency120 Hz ¡¾1%, 1 kHz ¡¾0.05% Level 0.1 V to 1.0 V, resolution 0.01 V, accuracy ¡¾10% Output mode Continuous, synchronous Source delay time 0 to 1.000 s, resolution 1 ms (Effective when Output mode is set to the synchronous mode) • Measurement cable length: 0 m, l m, 2 m (N.B., DC resistance of HCUR and LCUR cable : 0.3 §Ù or less per cable) • Measurement time mode: Short, Med, Long • Measurement range selection: Automatic (Auto), manual (Hold) • Measurement range: When the measurement frequency is 120 Hz: 10 nF, 100 nF, l µF, 10 µF, 100 µF, 1 mF. When the measurement frequency is 1 kHz: 1 nF, 10 nF, 100 nF, 1 µF, 10 µF, 100 µF. • Averaging: 1 to 256 times • Trigger mode: Internal (INT), manual (MAN), external (EXT), bus (BUS) • Trigger delay time: 0 to 1.000 s, resolution 1 ms Display range of measurement value Parameter Display range of measurement value Cs, Cp –9.9999 mF to –0.0001 nF, 0, 0.0001 nF to 9.9999 mF D –9.9999 to –0.0001, 0, 0.0001 to 9.9999 Q –9999.9 to –0.1, 0, 0.1 to 9999.9 Rs, Rp –999.99 M§Ù to –0.01 m§Ù, 0, 0.01 m§Ù to 999.99 M§Ù G –9.9999 kS to –0.0001 µS, 0, 0.0001µS to 9.9999 kS ∆% –999.99% to –0.01%, 0, 0.1% to 999.99 Measurement accuracy The accuracy is defined when all of the following conditions are met. • Warm up time is 30 min or more. • The OPEN and SHORT corrections have been

 

Display range of measurement value Parameter Display range of measurement value Cs, Cp –9.9999 mF to –0.0001 nF, 0, 0.0001 nF to 9.9999 mF D –9.9999 to –0.0001, 0, 0.0001 to 9.9999 Q –9999.9 to –0.1, 0, 0.1 to 9999.9 Rs, Rp –999.99 M§Ù to –0.01 m§Ù, 0, 0.01 m§Ù to 999.99 M§Ù G –9.9999 kS to –0.0001 µS, 0, 0.0001µS to 9.9999 kS ∆% –999.99% to –0.01%, 0, 0.1% to 999.99 Measurement accuracy The accuracy is defined when all of the following

 
 
»ç¾÷ÀÚµî·Ï¹øÈ£ 113-01-57596| ¼­¿ï½Ã ±¸·Î±¸ ±¸·Îº»µ¿1258 Áß¾ÓÀ¯Åë´ÜÁö °¡µ¿ 2413È£ Åë½ÅÆǸŠÁ¦ 1918È£ | ´ëÇ¥ÀÚ¸í ±èâ¼ö
ÀÎâ°èÃø±â ÀüÈ­ 02-2616-4851 Æѽº 02-2616-4852
Copyright ÀÎâ°èÃø±â 2008 All rights reserved.